Speech, spectral cue and harmony perception in cochlear implant recipients with anatomy-based fitting: a prospective, randomized, multicenter trial
Emilie Heuninck, Vedat Topsakal, Jaouad Abari, Dominik Riss, Linda Lüchtrath, Rudolfs Liepins, Freya Brauer, Thomas Thurner,
Key points
From the paper's conclusion- No statistically significant effect of fitting was found for pure-tone audiometry ( p = 0.23), speech perception in quiet ( p = 0.66), speech perception in noise ( p = 0.42) and self-perceived auditory benefit ( p = 0.29).
Abstract
Anatomy-based fitting (ABF) aims to restore natural tonotopicity by pre-operatively selecting an electrode array for complete cochlear coverage and post-operatively adapting the frequency allocation of a cochlear implant (CI) to a patient’s individual cochlear anatomy. The objective of this study was to assess the effect of ABF on speech, spectral cue and harmony perception in inexperienced CI recipients. Fifty-six newly unilaterally implanted patients with a bilateral severe-to-profound sensorineural hearing loss were included at the University Hospital Brussels, the Antwerp University Hospital and the University Hospital Vienna. Thirty patients were fitted with ABF and 26 patients with a standard fitting. Patients had follow-up visits at 1 week, 1 month, 3 months and 6 months post-activation of the audioprocessor. No statistically significant effect of fitting was found for pure-tone audiometry ( p = 0.23), speech perception in quiet ( p = 0.66), speech perception in noise ( p = 0.42) and self-perceived auditory benefit ( p = 0.29). Patients fitted with ABF demonstrated a better perception of auditory cues in the spectral domain ( p < 0.001) at 3 and 6 months post-activation, and a more distinct pattern for pleasantness of harmonic intervals in comparison to patients with a standard frequency distribution at 3 months post-activation. A higher contrast in pleasantness of harmonic intervals may enhance music perception and appreciation. Trail register: Clinicaltrails.gov with registration number NCT05451628 and date 02/06/2022 for University Hospital Brussels and Antwerp University Hospital and registration number NCT05684393 and date 04/01/2023 for University Hospital Vienna.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Refined anatomy-based fitting reduces interaural place mismatch and improves speech outcomes, with preliminary evidence for reduced listening effort.PloS one · 2026
- Evaluation of Fine Structure Coding in New Cochlear Implant Users with Tonotopic Fitting: a Prospective, Randomized, Double-Blind, Cross-Over Study.Clinical and experimental otorhinolaryngology · 2026
- Automated Optimization of Patient-Specific Electro-Anatomical Models Fitted to Cochlear Implant SCINSEVarXiv · 2026
- The Interphase Gap Effect in Cochlear Implant Users: Biological Basis, Parameter Selection, Analytical Methods, and Quantitative ScalesJournal of the Association for Research in Otolaryngology · 2026
- Improving Spectral Resolution via Simultaneous Extracochlear and Apical Ground Contacts: A Neural Simulation StudyarXiv · 2026
- Patient-reported benefit and speech perception in 24,570 hearing aid users: a nationwide study of the French Client-Oriented Scale of Improvement (COSI)medRxiv · 2026