Diagnostic accuracy of automated hematology analyzer abnormal flags for detecting hematological malignancies: A systematic review and meta-analysis
Zewudu Mulatie, Bruktawit Eshetu, Afework Habtamu Aseme, Sisay Desale, Saleamlak Sebsibe, Yonas Erkihun, Yeshimebet Kassa, Tesfaye Gessese,
Wollo University · Debre Berhan University
Key points
From the paper's conclusion- The pooled sensitivity and specificity of abnormal hematology analyzer flags for detecting hematological malignancies were 91% (95% CI: 87%-94%) and 89% (95% CI: 84%-92%), respectively, indicating good diagnostic accuracy.
Abstract
BACKGROUND: Hematological malignancies including leukemia, lymphoma, and myelodysplastic syndromes, are characterized by clonal proliferation of abnormal blood or bone marrow cells. Early and accurate detection is essential for improving treatment outcomes and survival. Automated hematology analyzers generate abnormal flags that may indicate underlying hematologic malignancies; however, their overall diagnostic accuracy has not been comprehensively evaluated. This systematic review and meta-analysis aimed to assess the diagnostic performance of abnormal flags for detecting hematological malignancies. METHODS: A systematic search of PubMed, PubMed Central, Scopus, ScienceDirect, and Google Scholar was conducted to identify relevant diagnostic accuracy studies. Methodological quality was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2(QUADAS-2) tool. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated using a bivariate random-effects model in Stata version 17.0. Heterogeneity was assessed using the I2 statistic, and subgroup and meta-regression analyses were performed to explore potential sources of variability. RESULTS: Twenty-eight studies met the inclusion criteria. The pooled sensitivity and specificity of abnormal hematology analyzer flags for detecting hematological malignancies were 91% (95% CI: 87%-94%) and 89% (95% CI: 84%-92%), respectively, indicating good diagnostic accuracy. Significant heterogeneity was observed across studies (I2 > 50%). Meta-regression analysis identified the type of abnormal flag as a significant source of heterogeneity in sensitivity (p < 0.001), whereas both the type of abnormal flag and the analyzer platform significantly influenced specificity. CONCLUSION: Automated hematology analyzer abnormal flags showed promising diagnostic performance. However, substantial heterogeneity and differences in analyzer platforms, flag types, and reference standards reduce the certainty and generalizability of pooled estimates. Nevertheless, these findings support the use of abnormal hematology analyzer flags as an effective initial screening tool in routine laboratory practice, particularly in resource-limited settings where rapid and cost-effective diagnostic support is essential. Systematic review registration PROSPERO (CRD42024601908).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Utility of WBC Scatterplots and Suspect Flags Generated by Beckman Coulter LH-750 Hematology Analyzer in the Characterization of Leukemias and Related Hematological Malignancies.Indian journal of hematology & blood transfusion : an official journal of Indian Society of Hematology and Blood Transfusion · 2026
- Multimodal AI in hematology: a systematic review of fusion approaches for automated diagnosis of blood disordersThe Egyptian Journal of Internal Medicine · 2026
- B-075 Can DIFF Scattergrams Predict Acute Leukemia Phenotype? A Standardized Interpretation Approach Using Mindray BC-6800PlusClinical Chemistry · 2026
- Diagnostic Accuracy and Prognostic Value of Flow Cytometry Versus PCR-Based Minimal Residual Disease Assessment in Leukemia: A Systematic Review and Meta Analysis.Cureus · 2026
- Beyond Analytical Agreement: Integrating Analytical Performance and Algorithm-Assisted Morphological Interpretation in a Comparative Evaluation of the Mindray BC-7800/BC-7900 and Sysmex XN-9100 Hematology Platforms.Diagnostics (Basel, Switzerland) · 2026
- Development and validation of a model for stratifying haematological malignancy risk in primary care using basic blood tests.British journal of haematology · 2026