Methods for analytical validation of novel digital clinical measures: A simulation study
Simon Turner, Chen Chen, Rolando Acosta, Rachell Chon, Eric Fernando Boeck Daza, Lysbeth Floden, Joss Langford, Leif Simmatis,
Digital Science (United States) · Regeneron (United States)
Key points
From the paper's conclusion- We quantified the ability of two methods to assess the latent relationship between reference and target measures: the Pearson Correlation Coefficient (PCC) and factor correlations from a two-factor confirmatory factor analysis (CFA) model.
Abstract
Analytical validation is a crucial step in the evaluation of algorithms that process data from sensor-based digital health technologies (sDHTs). Analytical validation of novel digital measures can be complicated when reference measures with directly comparable units are not available. To address this, we conducted a simulation study. Data was simulated assuming a latent physical ability trait, indirectly accessed through an sDHT-derived target measure collecting step count data, and the items of a clinical outcome assessment (COA) measuring self-reported physical activity. We quantified the ability of two methods to assess the latent relationship between reference and target measures: the Pearson Correlation Coefficient (PCC) and factor correlations from a two-factor confirmatory factor analysis (CFA) model. Additionally, three multiple linear regression models were used to evaluate if multiple COA reference measures can more completely represent a target measure of interest. Our findings show that PCC was more stable, easier to compute, and relatively robust with respect to violations of parametric assumptions than CFA, particularly with small sample sizes. However, CFA was less biased than PCC in all scenarios investigated. We demonstrate that using both PCC and CFA generates more confidence in the results of a target and reference measure comparison. Finally, regression results suggest that incorporating multiple reference measures with more frequent collection time points can provide a more complete presentation of the sDHT's analytical validity. Novel digital measures are being developed at an accelerating pace and promise to revolutionize patient care and medical product development. Our findings provide investigators with crucial information for choosing appropriate methods to perform rigorous analytical validation of these novel measures, including an open-access simulation toolkit.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Making patient-reported outcomes reusable at scale.The Lancet. Digital health · 2026
- Sensor-based digital health technologies to capture endpoints in recent clinical trials: a scoping reviewnpj Digital Medicine · 2026
- Statistical analysis of Likert-based ordinal scales: a guide for clinical trialistsBMC Medical Research Methodology · 2026
- Validating DigiHEALTHQUAL for measuring digital health effects on service quality in outpatient care in Germany.NPJ digital medicine · 2026
- An Expedited Chart Review Process for Large Database Studies Using Natural Language Processing and Multiwave Adaptive SamplingEpidemiology · 2026
- Construct validity of real-world digital mobility outcomes in patients after proximal femoral fracture: a cross-sectional observational studyScientific Reports · 2026