Comparison of Cobas Plasma Separation Cards and Whatman filter paper cards versus conventional serum samples for anti-Trypansoma cruzi antibody detection.
Aroa Silgado, Alejandro Mediavilla, Patricia Martínez-Vallejo, Carles Rubio-Maturana, Lidia Goterris, Pau Bosch-Nicolau, Inés Oliveira-Souto, Núria Serre-Delcor,
Department of Microbiology, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, PROSICS Barcelona, Spain. · Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain.
Key points
From the paper's conclusion- Antibody index values from Whatman-collected samples were higher than those from PSC-collected samples (median 96.45 vs.
Abstract
BACKGROUND: Diagnosis of chronic Trypanosoma cruzi infection relies on serological techniques using invasive blood samples (serum or plasma), which can be impractical in remote areas. Dried blood spot (DBS) sampling offer advantages over invasive samples in terms of ease of collection (finger prick), transport and storage. This study aimed to compare the performance of anti-T. cruzi antibody detection from DBS samples collected on two different devices: Whatman cards and Cobas Plasma Separation Cards (PSC). METHODOLOGY/PRINCIPAL FINDINGS: A prospective study using 382 paired serum and whole blood samples was conducted. Whole blood were used to obtain DBS collected on Whatman and PSC cards. All samples were tested for IgG anti-T. cruzi using the Elecsys Chagas assay, with serum serving as the gold standard. Both DBS collection systems showed high concordance with serum samples (>96%). However, antibody index values detected in DBS samples were lower than those detected in serum samples (p < 0.05). Qualitative results from DBS were highly concordant between the collection systems, with only two discrepancies (2/382), both positive on Whatman and negative on PSC. Antibody index values from Whatman-collected samples were higher than those from PSC-collected samples (median 96.45 vs. 63.33; p < 0.05). CONCLUSIONS/SIGNIFICANCE: DBS sampling is a feasible alternative to invasive blood collection, particularly in settings with limited access to health systems. Both DBS-collection devices showed high diagnostic accuracy; however, the lower antibody index values from PSC-collected samples may compromise the sensitivity of the technique in samples with a low antibody index.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Laboratory evaluation of five rapid diagnostic tests for the serological diagnosis of chronic Trypanosoma cruzi infection in Yucatan, MexicomedRxiv · 2026
- evaluation of the performance of rapid diagnostic tests in point-of-care conditions for serological diagnosis of chagas disease in pregnant women in Colombia.PLoS neglected tropical diseases · 2026
- Diagnostic Accuracy of a Commercial ELISA for Detecting Antibodies Against Strongyloides stercoralis in Dried Blood Spots: A Field Study in Puerto Iguazú, Argentina.Pathogens (Basel, Switzerland) · 2026
- B-042 Performance evaluation of Atellica IM infectious disease assays with dried blood spot sampleClinical Chemistry · 2026
- Stage-Informed Trypanosoma cruzi Antigen Selection Enhances Assay Concordance in the Evaluation of Discordant Chagas Disease Serology.Microorganisms · 2026
- Diagnostic Accuracy of the TR Chagas Bio-Manguinhos Rapid Test in the Municipality of Canguçu, Rio Grande do Sul, a Historically Endemic Area for Chagas Disease in Southern Brazil: a prospective study.Acta tropica · 2026