Multiscale axial displacement measurement based on radially segmented double-helix PSF and multi-feature hierarchical demodulation.
Liu Zhang, Mengyang Shi, Hua Liu, Shikai Zan, Yangyang Zou, Yang Zhu
National Engineering Research Center of Geophysics Exploration Instruments, Jilin University, Changchun 130061, China and the College of Instrumentation and Electrical Engineering, Jilin University, Changchun 130012, China. · Center for Advanced Optoelectronic Functional Materials Research, Changchun 130024, China, and also with the College of Physics, Northeast Normal University, Changchun 130024, China.
Key points
From the paper's conclusion- To overcome this limitation, we propose a fast axial displacement sensing method that integrates a radially segmented double-helix point spread function (RS-DHPSF) with multi-feature hierarchical demodulation.
Abstract
The double-helix point spread function (DH-PSF) inherently suffers from a trade-off between axial range and sensitivity, which limits its use in optical alignment and focal-plane tracking tasks that require both wide-range acquisition and high-precision localization. To overcome this limitation, we propose a fast axial displacement sensing method that integrates a radially segmented double-helix point spread function (RS-DHPSF) with multi-feature hierarchical demodulation. By tailoring the phase responses of the inner and outer radial zones, the RS-DHPSF simultaneously provides a wide axial capture range and high sensitivity in the central region. We further establish a non-ideal optical model incorporating phase quantization, physical noise, and residual aberrations to evaluate axial localization performance. To efficiently decode the complex RS-DHPSF patterns evolving with axial displacement, we further develop a hierarchical region-of-interest chirp z-transform normalized cross-correlation (ROI-CZT-NCC) algorithm constrained by multi-feature candidate intervals. Simulation and experimental results show that the proposed method reduces the per-frame localization time by approximately 90% while achieving a continuous axial measurement range of approximately 7 mm, with a mean absolute error (MAE) of 0.771 μm over the full range and a reduced MAE of 0.419 μm within the central ±250 μm region.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Adaptive phase aberration correction in off-axis digital holographic microscopy using distance-field-weighted Zernike fittingApplied Optics · 2025
- Efficient double helix detection with steerable filtersBiomedical Optics Express · 2026
- Adaptive carrier-aligned local spectral sampling for fast and accurate phase retrieval in off-axis digital holography.Optics letters · 2026
- Depth-robust super-resolution nanofabrication for 3D mesoscopic photonic structures.Nature nanotechnology · 2026
- Axial resolution post-processing engineering in Fresnel incoherent correlation holographyJournal of Physics Photonics · 2026
- Measurement of Form and Position Error of Small-Diameter Deep Holes Based on Collaboration Between a Lateral Confocal Displacement Sensor and Helical ScanningSensors · 2025