Estimating heart rate variability using facial video photoplethysmography: a pilot validation study
Leszek Pstras, Tymoteusz Okupnik, Beata Ponikowska, Bartłomiej Paleczny
Institute of Biocybernetics and Biomedical Engineering · Wroclaw Medical University
Key points
From the paper's conclusion- The results should be confirmed in a larger study with greater diversity in age and skin tone.
Abstract
ABSTRACT Introduction Video photoplethysmography (vPPG) employs a digital camera to detect blood pulsations in the skin vasculature, which can be used to estimate various physiological parameters. In this study, we investigate the accuracy and precision of two heart rate variability (HRV) indices estimated using a smartphone camera and the facial vPPG technology Shen.AI Vitals. Methods The study group included 35 healthy volunteers (17 females) with median age 25 years (range 20–42 years). The subjects were in a sitting position, keeping their heads relatively still. A smartphone mounted on a tripod was used to acquire 1-min video recordings of participants’ faces. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference values of two analysed time-domain HRV indices: SDNN and lnRMSSD. Results For SDNN, the mean absolute error (MAE) was 3.5 ms (11.0% in relative terms) and the root-mean-square error (RMSE) was 4.5 ms (15.7%). For lnRMSSD, the MAE was 0.24 (7.3%) and RMSE was 0.31 (9.9%). Correlations between the vPPG-based and ECG-based HRV values were strong, with the Pearson correlation coefficient of 0.98 for SDNN and 0.88 for lnRMSSD (P < 0.001 in both cases). Conclusions In a young, white population, the tested vPPG technology estimated HRV indices (SDNN and lnRMSSD) with acceptable accuracy in most subjects, with a slight systematic overestimation, especially for low values. The results should be confirmed in a larger study with greater diversity in age and skin tone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Contactless camera-based estimation of heart rate and variability from short facial video using remote photoplethysmography, remote ballistocardiography, and quality-aware selectionEuropean Heart Journal · 2026
- Accuracy of Photoplethysmography-Derived Pulse Rate Variability Compared with Electrocardiography-Derived Heart Rate Variability: A Systematic Review and Meta-Analysis.Sensors (Basel, Switzerland) · 2026
- Frequency-Preserving Readout Design and Error Characterization for CWT-Based rPPG Heart-Rate Estimation.Sensors (Basel, Switzerland) · 2026
- Cross-polarised temple photoplethysmography for motion-robust and equitable cardiovascular sensing in virtual reality.Biomedical optics express · 2026
- An observational study of the reliability and concurrent validity of heart rate variability devices in athletesFrontiers in Physiology · 2026
- Missed isochromatic cardiac pulsation in remote photoplethysmography: detection, impact, and removalBiomedical Optics Express · 2026