Applied optics

Multi-wavelength FMCW digital holography for high-accuracy and large-depth-range three-dimensional shape measurement.

Sota Kawabata, Hikaru Hamada, Varun Kumar, Masayuki Yokota

Graduate School of Natural Science and Technology, Major in Science and Engineering, Shimane University, Matsue, Shimane 690-0854, Japan.

Key points

From the paper's conclusion
  • Digital holography (DH) is a technique that enables both non-contact and highly precise measurement of the three-dimensional shapes of objects.

Abstract

Digital holography (DH) is a technique that enables both non-contact and highly precise measurement of the three-dimensional shapes of objects. However, in conventional DH with a single wavelength, the measurement range along the depth direction is limited to a half of the wavelength "λ." As a result, it becomes difficult to accurately obtain the object shapes beyond this range due to phase ambiguity. Multi-wavelength phase unwrapping can overcome this limitation by achieving both an extended measurement range and improved accuracy. To utilize this approach, a multiplexing technique is required to record holograms corresponding to multiple wavelengths simultaneously. In this study, based on our previous work in which we utilized frequency-modulated continuous-wave digital holography (FMCW-DH) to multiplex two wavelengths in the time-frequency domain, we extend the technique to three wavelengths. Unlike the previous two-wavelength method, the use of three optical wavelengths generates multiple synthetic wavelengths, enabling sequential multi-wavelength phase unwrapping. This approach combines the wide unambiguous measurement range provided by the longest synthetic wavelength with the higher height sensitivity provided by the shorter synthetic wavelengths. In experiments, a stepped object with a known step height of 1.00 mm was measured. The standard deviation of the height profile was reduced by a factor of 15 by unwrapping from the longest to the intermediate synthetic wavelength. However, subsequent unwrapping to the shortest synthetic wavelength resulted in an increased root mean square error (RMSE), indicating that systematic errors introduced by spectral leakage and crosstalk limited the measurement accuracy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Multi-wavelength FMCW digital holography for high-accuracy and large-depth-range three-dimensional shape measurement — Science Skim