From the paper's conclusion- The results demonstrate the capability of grating-based dual-angle digital holographic shear interferometry for quantitative three-dimensional surface reconstruction while maintaining a compact common-path configuration.
Abstract
In this work, a grating-based dual-angle digital holographic shear interferometry system is presented for generating synthetic wavelengths and extending the measurable height range. A geometric-phase (GP) grating and mirror configuration generates laterally sheared wavefronts at multiple shear orientations, while a polarization camera enables simultaneous phase-shifted intensity acquisition. Measurements are performed at two illumination angles, and the reconstructed complex wavefields are combined to obtain a synthetic phase distribution whose sensitivity is determined by the angular separation between the two measurements. The system was experimentally evaluated using standard step-height artifacts and surface features on both reflective and diffuse samples. Step-height measurements demonstrated the dependence of measurement performance on the selected synthetic wavelength. An analytical uncertainty analysis identified the illumination angle as a significant contributor to the overall measurement uncertainty, emphasizing the importance of system calibration using a standard artifact. Temporal repeatability was also evaluated through repeated measurements. The results demonstrate the capability of grating-based dual-angle digital holographic shear interferometry for quantitative three-dimensional surface reconstruction while maintaining a compact common-path configuration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-Axis Micro-Displacement Sensing Based on a Grating Pair with a Quasi-Common-Mode Optical Configuration.Micromachines · 2026
- Multi-shear strategy for high-sensitivity and wide-range shearography.Optics letters · 2026
- Speckle Angle: An Intrinsic Geometric Metric for High-Precision Speckle MetrologyarXiv · 2026
- Cross‐Scale High‐Precision Characterization for Three‐Dimensional Profiles of Curved Diffractive MicrostructuresSmall Methods · 2026
- Flexible Single-Shot Multi-Depth Full-Field Tomographic Imaging System Based on Spatial Frequency Division Multiplexing HolographyPhotonics · 2026
- Near-optical-coaxial phase measuring deflectometry for dual-sided specular components based on a prior parametric model.Optics express · 2026