Development of Microdialysis Probes in Series Approach Toward Eliminating Microdialysis Sampling Calibration: Miniaturization into a PDMS Microfluidic Device
Randy F. Espinal Cabrera
Key points
From the paper's conclusion- All the work conducted to achieve the development and miniaturization of the microdialysis probes in series approach is presented in this dissertation.
Abstract
A new microdialysis sampling method and microfluidic device were developed in vitro. The method consisted of using up to four microdialysis sampling probes connected in series to evaluate the relative recovery (RR) of different model solutes methyl orange, fluorescein isothiocyanate (FITC)-dextran average mol. wt. 4,000 (FITC-4), FITC-10, FITC-20, and FITC-40. Different flow rates (0.8, 1.0, and 1.5 µL/min) were used to compare experimentally observed relative recoveries with theoretical estimations. With increasing the number of probes in series, the relative recovery increases and ~100% (99.7% ± 0.9%) relative recovery for methyl orange was obtained. For larger molecules such as fluorescein isothiocyanate (FITC)-dextran average mol. wt. 4,000 (FITC-4), FITC-10, FITC-20, and FITC-40, RR of 66.3% ± 0.0%, 39.4% ± 0.6%, 18.7% ± 0.1%, and 7.7% ± 0.1%, respectively, were obtained using four microdialysis sampling probes in series at 0.8 µL/min. Using theoretical estimations, the number of microdialysis probes in series needed to achieve 99% RR was determined for each solute. The theoretical estimations started deviating from experiments at mol. wt. 10,000 (FITC-10). For example, the deviations from experiments for FITC-10, FITC-20, and FITC-40 were +52%, +149%, and +179% respectively. On the other hand, methyl orange and FITC-4 theoretical estimations were closer to the experiments (-1%, underestimation, and +15%, overestimation). The method developed for this dissertation was miniaturized in a polydimethylsiloxane (PDMS) microfluidic device having a flat polyethersulfone membrane and seven micro-channels connected in series. Push-pull experiments determined that the optimal setting for this microfluidic device prototype during the collection of methyl orange was 0.2 µL/min-1.0 µL/min. The relative recovery of methyl orange using this setting was 78.8% ± 2.5%. This result indicated that a working microfluidic device prototype was developed. Further optimizations need to be performed to reach the same level as the microdialysis probes in series method. All the work conducted to achieve the development and miniaturization of the microdialysis probes in series approach is presented in this dissertation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A scalable microfluidic dialyzer enabling low-flow hemodialysis with clinically relevant clearance.Journal of membrane science · 2026
- Automated online microdialysis coupled with capillary electrophoresis via a three-layer PDMS microchip cast in 3D-printed moulds for rapid profiling of free amino acids in milk.Talanta · 2026
- A Microfluidic TFF Device for Biopharmaceutical Process Development: Scale-Down Verification of Ultrafiltration and Diafiltration Modes for Monoclonal Antibodies.Biotechnology and bioengineering · 2026
- Microfluidic diffusional sizing in bioanalysis and biosensing.Lab on a chip · 2026
- Ocular microdialysis in preclinical pharmacokinetic studies: Principles, challenges, and practical insights.Journal of pharmaceutical sciences · 2026
- Label-Free In-Situ Estimation of Microparticle Concentration in Micro-Optofluidic Device.Sensors (Basel, Switzerland) · 2026