Journal of orthopaedic case reports

Stress-Related Acromion Base Fracture after Clavicular Hook Plate Fixation: A Case Report.

Yi-Hsuan Chen, Shun-Min Chang, Chao-Tse Chiu, Cheng-Chang Lu

Department of Orthopedics, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. · Department of Orthopedics, Kaohsiung Municipal Siao-Gang Hospital, Kaohsiung, Taiwan.

Case report

Key points

From the paper's conclusion
  • This case illustrates a rare stress-related fracture of the acromion base following clavicular hook plate fixation, with a fracture pattern distinct from the typical hook plate cut-out mechanism. Awareness of this potential complication and individualized surgical management based on fracture morphology and shoulder girdle stability are essential for achieving favorable outcomes.

Abstract

INTRODUCTION: Clavicular hook plate fixation is widely used for the surgical management of high-grade acromioclavicular (AC) joint injuries and generally provides reliable clinical outcomes. Nevertheless, implant-related complications involving the acromion have been reported. Stress-related fractures at the base of the acromion following hook plate fixation are extremely rare and remain poorly described in the literature. CASE REPORT: A 48-year-old woman sustained a high-grade AC joint injury and underwent open reduction and internal fixation with a clavicular hook plate. Two months after surgery, she presented with acute shoulder pain and functional limitation following minor trauma. Imaging studies revealed failure of the hook plate construct associated with a displaced fracture at the base of the acromion, resulting in compromise of the subacromial space. The patient was treated surgically with implant removal, fixation of the acromial fracture using a tension-band technique, and restoration of AC and coracoclavicular stability. Post-operative imaging demonstrated satisfactory reduction, and the patient achieved functional recovery during follow-up. CONCLUSION: This case illustrates a rare stress-related fracture of the acromion base following clavicular hook plate fixation, with a fracture pattern distinct from the typical hook plate cut-out mechanism. Awareness of this potential complication and individualized surgical management based on fracture morphology and shoulder girdle stability are essential for achieving favorable outcomes.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers