Stress-Related Acromion Base Fracture after Clavicular Hook Plate Fixation: A Case Report.
Yi-Hsuan Chen, Shun-Min Chang, Chao-Tse Chiu, Cheng-Chang Lu
Department of Orthopedics, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan. · Department of Orthopedics, Kaohsiung Municipal Siao-Gang Hospital, Kaohsiung, Taiwan.
Key points
From the paper's conclusion- This case illustrates a rare stress-related fracture of the acromion base following clavicular hook plate fixation, with a fracture pattern distinct from the typical hook plate cut-out mechanism. Awareness of this potential complication and individualized surgical management based on fracture morphology and shoulder girdle stability are essential for achieving favorable outcomes.
Abstract
INTRODUCTION: Clavicular hook plate fixation is widely used for the surgical management of high-grade acromioclavicular (AC) joint injuries and generally provides reliable clinical outcomes. Nevertheless, implant-related complications involving the acromion have been reported. Stress-related fractures at the base of the acromion following hook plate fixation are extremely rare and remain poorly described in the literature. CASE REPORT: A 48-year-old woman sustained a high-grade AC joint injury and underwent open reduction and internal fixation with a clavicular hook plate. Two months after surgery, she presented with acute shoulder pain and functional limitation following minor trauma. Imaging studies revealed failure of the hook plate construct associated with a displaced fracture at the base of the acromion, resulting in compromise of the subacromial space. The patient was treated surgically with implant removal, fixation of the acromial fracture using a tension-band technique, and restoration of AC and coracoclavicular stability. Post-operative imaging demonstrated satisfactory reduction, and the patient achieved functional recovery during follow-up. CONCLUSION: This case illustrates a rare stress-related fracture of the acromion base following clavicular hook plate fixation, with a fracture pattern distinct from the typical hook plate cut-out mechanism. Awareness of this potential complication and individualized surgical management based on fracture morphology and shoulder girdle stability are essential for achieving favorable outcomes.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Osteosynthesis of an acromion fracture using a proximal clavicle plate: a case report.Journal of surgical case reports · 2026
- Biomechanical impact of sagittal plane clavicle hook plate positioning on subacromial stress.Asia-Pacific journal of sports medicine, arthroscopy, rehabilitation and technology · 2026
- Clinical outcomes for acute grade III and V acromioclavicular dislocations using hook plates and double-button fixation with a two-year follow-upEuropean Journal of Orthopaedic Surgery & Traumatology · 2026
- Fibular Strut Allograft Reconstruction for Distal Clavicle Bone Loss in Revision Acromioclavicular Joint Instability.Video journal of sports medicine · 2026
- Arthroscopic Double EndoButton Adjustable-Loop Plate Fixation for Acute Acromioclavicular Joint Dislocation.Arthroscopy techniques · 2026
- Semitendinosus Tendon Reconstruction for Recurrent Acromioclavicular Joint Instability Following Repeated Fixation Failure and Postoperative Trauma: A Case Report.Acta orthopaedica et traumatologica turcica · 2026