Biomechanical impact of sagittal plane clavicle hook plate positioning on subacromial stress.
Jung-Min Lee, Jae-Hoo Lee
Department of Orthopedic Surgery, Keimyung University Dongsan Hospital, Daegu, Republic of Korea. · Department of Orthopaedic Surgery, Inje University, Ilsan Paik Hospital, Goyang-si, Republic of Korea.
Key points
From the paper's conclusion- Posterior position of the hook plate in the sagittal plane significantly reduced subacromial pressure and contact area compared to neutral or anterior positions. Additionally, internal and external rotations of the clavicle further increased subacromial stress, indicating the importance of considering clavicular movement in clinical settings. Within the biomechanical test, these findings suggest that posterior positioning of the hook plate may help attenuate subacromial stress and could thereby have the potential to reduce the likelihood of subacromial bone erosion; however, further clinical or finite-element validation is warranted before this can be translated into a clinical recommendation for the surgical treatment of high-grade AC joint dislocations.
Abstract
INTRODUCTION: In open reduction and hook plate fixation for high-grade acromioclavicular (AC) joint dislocation, proper placement of the hook plate is crucial in preventing subacromial osteolysis and improving clinical outcomes. This study aimed to identify the optimal sagittal plane positioning of the hook plate to minimize subacromial stress and erosion. MATERIALS AND METHODS: Six pairs of artificial bone models, designed to mimic human clavicle and scapula anatomy, were used to assess the biomechanical effects of three hook plate positions: anterior (group A), neutral (group N), and posterior (group P). Each model was equipped with a 5-hole clavicle hook plate secured with 3.5-mm locking screws. A pressure sensor measured contact pressures and areas under sagittal rotations. The clavicle and scapula were fixed in customized jigs, and physiological loading conditions were simulated with a preload of 20 N and a 70 N upward force on the clavicle. Clavicular rotations of 15° internal and external were applied to evaluate their effect on contact pressures. RESULTS: Group P showed a significantly lower mean pressure (1.27 MPa) than group A (1.92 MPa, p < 0.01) and group N (1.83 MPa, p < 0.01). Maximum pressure in group P (1.37 MPa) was also significantly lower than in group A (2.75 MPa, p < 0.01) and group N (2.34 MPa, p < 0.01). The contact area was smallest in group P (11.00 mm2) compared to group A (19.00 mm2, p < 0.01) and group N (17.00 mm2, p < 0.01). Clavicular rotations significantly increased subacromial pressure and contact area at all plate positions compared to the neutral position (p < 0.01). CONCLUSION: Posterior position of the hook plate in the sagittal plane significantly reduced subacromial pressure and contact area compared to neutral or anterior positions. Additionally, internal and external rotations of the clavicle further increased subacromial stress, indicating the importance of considering clavicular movement in clinical settings. Within the biomechanical test, these findings suggest that posterior positioning of the hook plate may help attenuate subacromial stress and could thereby have the potential to reduce the likelihood of subacromial bone erosion; however, further clinical or finite-element validation is warranted before this can be translated into a clinical recommendation for the surgical treatment of high-grade AC joint dislocations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Stress-Related Acromion Base Fracture after Clavicular Hook Plate Fixation: A Case Report.Journal of orthopaedic case reports · 2026
- Scapular depression represents a grade-independent component of acute acromioclavicular joint instabilityBMC Musculoskeletal Disorders · 2026
- Clinical and Radiographic Outcomes of Suture Anchor Repair versus Transarticular Kirschner Wire Fixation of the Acromioclavicular Joint in Acute High-grade Dislocation: A Randomized Clinical Trial.Journal of shoulder and elbow surgery · 2026
- Clinical outcomes for acute grade III and V acromioclavicular dislocations using hook plates and double-button fixation with a two-year follow-upEuropean Journal of Orthopaedic Surgery & Traumatology · 2026
- Anatomical Conoid Ligament Reconstruction Improves Posterior Stability in Neer Type IIB Distal Clavicle Fractures: A Cadaveric Biomechanical Study.Journal of shoulder and elbow surgery · 2026
- Index Metacarpal Fracture Risk in Suture Button Suspensionplasty and the Effects of Drill Hole Position: A Cadaveric Study.The Journal of hand surgery · 2026