科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ Frontiers in cardiovascular medicine2026-01-01

Label-efficient cross-population transfer learning for electrocardiographic risk stratification: evaluation across German, Chinese and US cohorts.

Yan Wang, Yan Lu

一句话结论 · In one sentence

Cross-population transfer of ECG models is feasible with label-efficient fine-tuning of a compact, interpretable feature backbone, and the resulting composite diagnostic score remains well-calibrated in a geographically distinct population. Subgroup heterogeneity nonetheless persists, with lower discrimination in participants aged 65 years and over and a sex-dependent calibration slope, and requires further validation.

原始摘要(英文原文)· Original abstract
BACKGROUND: Electrocardiography (ECG) is the most widely deployed cardiac screening modality, but demographic, acquisition and label-space heterogeneity across cohorts obstructs clinical translation. Cross-population studies rarely quantify which conditions transfer, how much target labelling is needed, or whether the adapted score stays calibrated and clinically useful. METHODS: We harmonised 12,521 recordings from PTB-XL (Germany; 7,371 records, 6,643 patients), Chapman-Ningbo (China; 4,574) and the MIT-BIH Arrhythmia Database (USA; 576 segments, 48 recordings) into 13 SNOMED-CT super-classes. A 38-dimensional interpretable feature set, computed in physical units and standardised on the source training partition alone, fed a compact multi-task backbone (30,400 parameters) trained on patient-separated partitions. It was evaluated zero-shot on both targets and adapted with 5%-50% of Chapman-Ningbo labels by linear probing on the frozen embedding, with partial and full fine-tuning as comparators; prevalence-aware sampling made four target classes (NORM, STD, LVH, TINV) evaluable. The composite diagnostic score was recalibrated on a dedicated split and assessed on untouched test data using bootstrap intervals, Holm-corrected comparisons and subgroup interaction tests. RESULTS: The source backbone reached macro-AUROC 0.866 (0.837-0.891) across 13 classes. Zero-shot transfer recovered 88% of the four-class source reference on Chapman-Ningbo (0.754, 0.727-0.779) and 0.642 (0.546-0.735, record-clustered) on MIT-BIH. Linear probing reached 0.795 with 5% of target labels and 0.829 with 50%, below the four-class source reference of 0.859; after Holm correction the gain over zero-shot was significant for NORM (+0.135), STD (+0.093) and TINV (+0.065) but not LVH (+0.004). Full fine-tuning added 0.021 at 50% labels but was inferior at 5% and less well calibrated. The recalibrated composite score attained AUROC 0.791 (0.743-0.836), Brier score 0.055 and expected calibration error 0.018 on Chapman-Ningbo, where 97% of positives were left-ventricular hypertrophy, and 0.834 on the seven-condition PTB-XL composite. Discrimination varied across age strata (0.708-0.863; interaction p = 0.012). CONCLUSION: Cross-population transfer of ECG models is feasible with label-efficient fine-tuning of a compact, interpretable feature backbone, and the resulting composite diagnostic score remains well-calibrated in a geographically distinct population. Subgroup heterogeneity nonetheless persists, with lower discrimination in participants aged 65 years and over and a sex-dependent calibration slope, and requires further validation.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Label-efficient cross-population transfer learning for electrocardiographic risk stratification: evaluation across German, Chinese and US cohorts. — 科研速览 Science Skim