Maximizing stem body size may reduce the risk of postoperative periprosthetic fractures : an analysis of 2,757 CPT femoral components.
Bernard H van Duren, Amy M Firth, Jonathan France, Jessica Nightingale, Benjamin V Bloch, Andrew R Manktelow, Mark Higgins
Nottingham Elective Orthopaedic Services, Nottingham University Hospitals NHS Trust, Nottingham, UK.
Key points
From the paper's conclusion- The findings show that, for a given offset, a larger femoral component (reducing the construct ratio) was associated with a lower risk of POPPF. Surgeons should aim to maximize the size of the femoral component to optimize the 'torsional resistance' of the femoral component relative to their reconstructed offset to reduce the risk of POPPF.
Abstract
AIMS: There is concern around an increased risk of postoperative periprosthetic fracture (POPPF) with cemented polished taper slip (PTS) femoral components. We hypothesized that femoral constructs resulting in increased load on the cement mantle would be associated with higher POPPF risk. The aim of this study, based on our hypothesis, was to undertake an analysis of a large cohort of PTS femoral components to understand the role of implant construct variations on the incidence of POPPF. METHODS: We retrospectively reviewed 2,757 patients undergoing THA with a PTS femoral component between January 2009 and December 2021. POPPFs were identified using a combination of linked Hospital Episode Statistic, National Joint Registry data, and local records. All fractures were confirmed with review of radiographs and documentation. Demographic data and implant details were collected. Associations between POPPF and potential contributory variables were assessed using univariate and multivariate regression analyses. RESULTS: In total, 40 POPPFs (1.45%) were identified at a mean of 6.4 years (SD 2.9; 0.2 to 10.1) from index procedure. Patients with POPPFs were older (mean age 74.5 years; SD 8.6) than the overall cohort (p < 0.001). BMI, height, weight, and American Society of Anesthesiologists grade were not different. Most fractures were type B (B1 65%, B2 17.5%, B3 5%). One fracture (B1) was managed conservatively, seven (17.5%) were revised, and 32 (80%) fixed. Multivariate analysis showed increased POPPF risk with age (odds ratio (OR) 1.076), but no other patient factors were significant. Offset (OR 1.13, 95% CI 1.04 to 1.22) and construct ratio (head + neck offset/femoral component-size) (OR 3.92; 95% CI 1.31 to 11.79) were strongly predictive. CONCLUSION: The findings show that, for a given offset, a larger femoral component (reducing the construct ratio) was associated with a lower risk of POPPF. Surgeons should aim to maximize the size of the femoral component to optimize the 'torsional resistance' of the femoral component relative to their reconstructed offset to reduce the risk of POPPF.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Periprosthetic Femoral Fracture in Hip Arthroplasty Using Cemented Stems: Toward a Construct-Level and Time-Dependent Perspective.Bioengineering (Basel, Switzerland) · 2026
- Collared cemented femoral stems are associated with lower periprosthetic femoral fracture rates: A systematic review and subgroup meta-analysis.Journal of experimental orthopaedics · 2026
- Collared, Uncemented Stems Markedly Reduce Periprosthetic Femoral Fracture Risk in Women ≥ 70 Years: A Swiss National Registry Study.The Journal of arthroplasty · 2026
- Periprosthetic femoral fracture risk varies across cemented femoral stem designs: a nationwide Swiss joint registry study.International orthopaedics · 2026
- Increased Risk of Periprosthetic Femoral Fracture with Cementless Collared Metadiaphyseal-Filling Stems Compared to Cemented Fixation for Femoral Neck Fractures in Patients Aged 65 Years or Older: An American Joint Replacement Registry Analysis.The Journal of arthroplasty · 2026
- Periprosthetic femoral fracture following primary hip arthroplasty : should the choice of femoral component design and fixation method vary according to the sex and age of the patient?The bone & joint journal · 2026