Objective arthrometric assessment of sagittal stability after total knee arthroplasty : a prospective cohort study.
Fabio Mancino, Heidi K Wilson, Mikhil Jain, Matthias Wittauer, Simone Brockman, Omar Khorshid, Christopher W Jones
Department of Orthopaedics, Fremantle Hospital, Fremantle, Australia.
Key points
From the paper's conclusion- PS implants demonstrated lower anterior translation under arthrometric testing compared with CR implants. However, this mechanical difference did not translate into superior short-term functional outcomes, and no correlation was found between arthrometric stability and PROMs. ROM improved in both groups without design-related differences.
Abstract
AIMS: To assess sagittal stability in vivo using an automated arthrometer and to evaluate its relationship with patient-reported outcomes (PROMs) and range of motion (ROM) following primary total knee arthroplasty (TKA). METHODS: This prospective, double-blind cohort study included 80 patients. Either posterior-stabilized (PS) rotating platform (RP) or a fixed bearing cruciate-retaining (CR) design was used. Clinical outcomes were collected preoperatively, at three and 12 months, using the Oxford Knee Score (OKS), Knee injury and Osteoarthritis Outcome Score (KOOS), Patient Knee Implant Performance (PKIP) score, and EQ-5D-5L questionnaire. Sagittal stability was measured using the GNRB/Dyneelax arthrometer. Differences were analyzed using paired t-tests and analysis of variance; correlations and multivariable regression were used to identify predictors of stability. RESULTS: All PROMs improved from baseline (p < 0.001). CR knees showed greater early PKIP improvement at three months 12.8 (SD 6.5) vs 8.4 (SD 7.6); p = 0.007). At both three and 12 months, PS knees demonstrated reduced anterior tibial translation across all loads (e.g. 6.2 mm (SD 2.3) vs 4.7 mm (SD 1.6) at 150 N; p = 0.002). Multivariable regression confirmed that implant design (p = 0.016) and sex (p < 0.001) were independent predictors of stability. No correlation was found between sagittal stability and PROMs. Overall, ROM remained unchanged at three months but improved significantly at 12 months. No differences in flexion were noted between the CR and PS groups. CONCLUSION: PS implants demonstrated lower anterior translation under arthrometric testing compared with CR implants. However, this mechanical difference did not translate into superior short-term functional outcomes, and no correlation was found between arthrometric stability and PROMs. ROM improved in both groups without design-related differences.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prediction model-based comparison of medial stabilized and cruciate-retaining total knee arthroplasty: A two-phase study.The Knee · 2026
- Clinical outcomes and patient-reported joint noise after total knee arthroplasty using saddle-shaped rotating-platform and bi-cruciate-stabilized implant-surgical systems: a propensity score-matched cohort study.Arthroplasty (London, England) · 2026
- Cruciate-retaining versus condylar-stabilized reconstruction strategies in robotic-arm assisted total knee arthroplasty: a prospective, double-blinded, randomized controlled trial.Journal of robotic surgery · 2026
- The Effect of Posterior Tibial Slope Change on Functional Outcomes After Posterior-Stabilized Total Knee Arthroplasty: An Analysis of 370 Patients Who Had A Minimum 4-Year Follow-Up.The Journal of arthroplasty · 2026
- Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study.Journal of robotic surgery · 2026
- Medial Pivot Total Knee Arthroplasty: Replicating Native Knee Kinematics and Early Clinical Outcomes.Indian journal of orthopaedics · 2026