Clinical outcomes of posterior-stabilized versus cruciate-retaining ANTHEM total knee arthroplasty using imageless robotic-assisted personalized alignment: a retrospective comparative cohort study.
Ali Albelooshi, Elhadi Babikir, Zainab Aqeel Khan, Abdallah Reda Bedair Elgouhary, Saeed Al Thani
Department of Orthopedic Surgery, Mediclinic City Hospital, Dubai, United Arab Emirates. · Department of Orthopedic Surgery, Mediclinic City Hospital, Dubai, United Arab Emirates. elhadibabiker84@hotmail.com.
Key points
From the paper's conclusion- This study compared 2-year patient-reported outcomes, responder rates, complications, and revisions between PS and CR ANTHEM TKA using imageless robotic-assisted personalized alignment.
Abstract
Posterior-stabilized (PS) and cruciate-retaining (CR) total knee arthroplasty (TKA) show no consistent clinical superiority. This study compared 2-year patient-reported outcomes, responder rates, complications, and revisions between PS and CR ANTHEM TKA using imageless robotic-assisted personalized alignment. This retrospective cohort included 858 primary ANTHEM TKAs (167 CR and 691 PS). All procedures used CORI robotic-assisted personalized alignment. Outcomes included the Knee injury and Osteoarthritis Outcome Score for Joint Replacement (KOOS-JR), visual analog scale (VAS) pain, satisfaction, and general health scores. Entropy-balanced inverse probability weighting adjusted for baseline differences. Responder rates and time to patient acceptable symptom state (PASS) were evaluated. After weighting, measured covariates were balanced and KOOS-JR improved substantially in both groups and did not differ at any postoperative time point. At 1 year, adjusted KOOS-JR scores were 84.1 for CR and 84.7 for PS (difference, - 0.61; 95% CI, - 2.80 to 1.58; p = .58); at 2 years, scores were 86.4 and 86.7, respectively (difference, - 0.38; 95% CI, - 2.31 to 1.55; p = .70). VAS pain, general health, satisfaction, and responder rates were also similar after multiplicity correction. CR patients achieved PASS earlier, but both groups exceeded 99% by 2 years. Complications occurred in 2 CR cases (1.2%) and 7 PS cases (1.0%); revisions occurred in 0 and 6 cases (0.9%), respectively. Using imageless robotic-assisted personalized alignment, CR and PS ANTHEM TKA produced substantial and comparable improvements in pain and patient-reported outcomes. CR was associated with earlier PASS achievement, but final outcomes and short-term complication and revision rates did not differ significantly.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cruciate-retaining versus condylar-stabilized reconstruction strategies in robotic-arm assisted total knee arthroplasty: a prospective, double-blinded, randomized controlled trial.Journal of robotic surgery · 2026
- Comparable clinical outcomes but different postoperative Dynamic Alignment of the Knee (DyAK) patterns between cruciate-retaining and posterior-stabilized inserts in functionally aligned robotic-assisted total knee arthroplasty.Journal of experimental orthopaedics · 2026
- Early Revision Rates and Clinical Outcomes of Two Cementless Cruciate-Retaining Total Knee Arthroplasty Designs at Two-Year Follow-Up: A Propensity Score-Adjusted Comparative Analysis.Medicina (Kaunas, Lithuania) · 2026
- Effect of Prosthesis Selection on Gap Balancing in Robotic-Assisted Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty: A Prospective Randomized Controlled Trial.The Journal of arthroplasty · 2026
- Comparison of Functional and Mechanical Alignment in Robotic- and Computer-Assisted Posterior-Stabilized Total Knee Arthroplasty: Clinical and Patient-Reported Outcomes from a Propensity-Matched Cohort Study.Orthopaedics & traumatology, surgery & research : OTSR · 2026
- Postoperative outcomes after conventional, robotic-arm-assisted, and pressure-sensor-guided cruciate-retaining total knee arthroplasty: a retrospective cohort study.Journal of robotic surgery · 2026