In vivo quantification of polyethylene wear in total ankle arthroplasty : a longitudinal study using weightbearing CT.
Francois Lintz, Alessio Bernasconi, Wolfram Grün, Enrico Pozzessere, Emily Luo, Pierre-Henri Vermorel, Albert Anastasio, Mark Easley,
Department of Foot and Ankle Surgery, Ramsay Healthcare, Clinique de l'Union, Saint Jean, France. · Orthopaedic Department, University of Napoli Federico II Hospital, Napoli, Italy.
Key points
From the paper's conclusion- Using a WBCT-based approach, this study enabled longitudinal in vivo quantification of PE wear in TAA. Wear rates (~11.3 mm³/year) aligned with prior estimates, and the method correctly identified anticipated predictors of increased wear.
Abstract
AIMS: In vivo assessment of polyethylene (PE) wear in total ankle arthroplasty (TAA) relies on approximation using 2D metal interspace height (2D-MIH) loss on weightbearing radiographs. Weightbearing CT (WBCT), combined with distance mapping, may improve quantification of PE wear over time using 3D metal interspace volume (3D-MIV) loss. This study aimed to assess 3D-MIV with successive WBCT scans. We hypothesized that WBCT based 3D-MIV would enable longitudinal quantification of PE wear and identify predictors. METHODS: This retrospective study included 29 ankles from 28 TAA patients (16 men, mean age 57.9 years (SD 10.5), BMI 26.3 kg/m² (SD 4.1)) who had WBCT scans at minimum two-year intervals. Patients aged below 18 years, and those with trauma or surgical procedures affecting ankle alignment between scans, were excluded. Demographic data, implant types, and clinical outcomes were extracted. 3D-MIV was measured after segmentation of individual bones and prosthetic components. Annualized approximated wear rates were calculated. Correlations and multivariate regression analyses were used to identify predictors. RESULTS: Mean follow-up between scans was 58.7 months (SD 17.9). Mean 3D-MIV decreased from 3.92 mL (SD 1.17) initially to 3.86 mL (SD 1.11) (p = 0.015). Yearly 3D-MIV loss was -11.34 mm³/year (SD 19.62). Correlations existed between 3D-MIV loss and coronal plane rotation (ρ = -0.58, p < 0.001), mediolateral translation (ρ = -0.52, p = 0.004, superoinferior translation (ρ = 0.56, p = 0.002) and BMI ≥ 27 kg/m² (p = 0.037). Multivariate regression identified coronal plane alignment (β = -3.66, 95% CI -7.31 to -0.01), p = 0.049) and mediolateral translation (β = -9.97, 95% CI -18.48 to -1.45), p = 0.024) as predictors of 3D-MIV loss. CONCLUSION: Using a WBCT-based approach, this study enabled longitudinal in vivo quantification of PE wear in TAA. Wear rates (~11.3 mm³/year) aligned with prior estimates, and the method correctly identified anticipated predictors of increased wear.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Three-dimensional surface morphology of retrieved polyethylene inserts and component alignment in failed total ankle arthroplasty: A Basic retrieval study.Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association · 2026
- Coronal alignment-related mediolateral load distribution and polyethylene wear in a medial-pivot total knee arthroplasty design.Archives of orthopaedic and trauma surgery · 2026
- Weightbearing CT in the Evaluation of Athletic Foot and Ankle Injuries.Current reviews in musculoskeletal medicine · 2026
- Radiological and Clinical Evaluation of the Ipsilateral Ankle of Patients Who Underwent Total Knee Arthroplasty: A Prospective Study.Journal of clinical medicine · 2026
- CT-Based Radiostereometric Analysis: A Promising Alternative to Conventional Radiostereometric Analysis in Determining Polyethylene Wear in Total Hip Arthroplasty.Advances in orthopedics · 2026
- Accuracy of implant positioning in total ankle arthroplasty using patient-specific instrumentation: A weightbearing CT analysis of landmark-based parameters.Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons · 2026