A Comparison of Different Models to Compute Cardiac Output by Open-Circuit Inert Gas Wash-In.
Robin Faricier, Daniel W Gregory, Daniel A Keir
School of Kinesiology, The University of Western Ontario, London, Ontario, CANADA.
Key points
From the paper's conclusion- These findings demonstrate that breathing frequency can meaningfully influence C2H2-derived Q̇ estimates and that computational models differ markedly in their sensitivity to ventilatory pattern. GAN appears to be the most robust to altered breathing frequency compared to WAG and ITER. Consistency in model selection is essential when using inert-gas uptake techniques to assess Q̇ during exercise.
Abstract
PURPOSE: Cardiac output (Q̇) can be measured non-invasively during exercise using the open-circuit acetylene (C2H2) uptake method. However, it is unclear whether different calculation techniques for these breathing-based Q̇ measurements yield consistent values and how variations in breathing patterns affect them. This study compared breathing-derived Q̇ estimates from three validated models (Wagner et al.: WAG, Gan et al.: GAN, and Iterative: ITER) and examined the effect of doubling breathing frequency on these estimates during continuous cycling exercise. METHODS: Fourteen healthy adults completed two 28-min constant-work-rate cycling stages at moderate (MOD) and heavy (HVY) intensities. At each stage, Q̇ was measured under normal, self-selected breathing (NF) and under controlled high-frequency breathing (HF) at 200% of NF. For every C2H2 uptake trial, Q̇ was calculated using WAG, GAN, and ITER models. RESULTS: Doubling breathing frequency had model-specific effects on Q̇ estimates. WAG produced significantly lower Q̇ during HF breathing compared with NF at both MOD (3.3±1.1 L·min -1; p<0.001) and HVY (2.8±1.8 L·min -1; p<0.001) intensities. In contrast, ITER yielded significantly higher Q̇ under high-frequency breathing (MOD: -1.7±1.0 L·min -1 and HVY: -3.0±1.6 L·min -1; p<0.001 for both). GAN showed only a small significant difference between breathing conditions at MOD (-0.4±0.7 L·min -1; p=0.039), but not at HVY (p=0.845). CONCLUSIONS: These findings demonstrate that breathing frequency can meaningfully influence C2H2-derived Q̇ estimates and that computational models differ markedly in their sensitivity to ventilatory pattern. GAN appears to be the most robust to altered breathing frequency compared to WAG and ITER. Consistency in model selection is essential when using inert-gas uptake techniques to assess Q̇ during exercise.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validity and reliability of the Vyntus CPX metabolic gas analyzer compared with the Douglas Bag method.European journal of applied physiology · 2026
- A framework for estimating cardiorespiratory fitness from diverse exercise tests.Npj exercise medicine and health · 2026
- Agreement of four metabolic equations for estimating submaximal cycling oxygen uptake with two portable indirect calorimetry systems in untrained young women.BMC sports science, medicine & rehabilitation · 2026
- Physiologic Stress During Walking and Cycling Early After Cardiac Surgery.Journal of cardiopulmonary rehabilitation and prevention · 2026
- Exercise intensity alters the relationship between breath acetone output and oxygen uptake during cycling exercise: a comparison of submaximal and incremental maximal protocols.Journal of breath research · 2026
- Muscle and cerebral oxygenation during repeated Wingate cycling in hypoxia and normoxia in male middle-distance runnersJournal of Sports Sciences · 2026