Consumer Grade Wearable Sensor Metrics Are Associated with Internal Forces at Common Running Injury Locations.
John J Davis Iv, Stacey A Meardon, John S Raglin, Andrew W Brown, Jaroslaw Harezlak, Allison H Gruber
Department of Kinesiology, School of Public Health - Bloomington, Bloomington, IN. · Department of Physical Therapy, East Carolina University, Greenville, NC.
Key points
From the paper's conclusion- Runners with higher-than-average cadence, vertical oscillation, or vertical ratio values experience marked differences in internal forces at the Achilles tendon and patellofemoral joint. Of these gait metrics, cadence is the most practical for out-of-lab use because of its ease of accurate measurement with consumer-grade devices.
Abstract
INTRODUCTION: Inexpensive consumer-grade wearable sensors have expanded possibilities to assess, monitor, or modify a runner's gait. However, it is unclear which sensor-measured gait metrics are strongly associated with internal loading at common injury locations. PURPOSE: To measure the association between gait metrics measured by consumer-grade wearable sensors and internal forces at the Achilles tendon and the patellofemoral joint. METHODS: 55 healthy runners wearing consumer-grade chest straps foot-pods completed a 38-minute run on an instrumented treadmill at 12 speeds from 70%-125% of self-reported typical running pace. A scaled musculoskeletal model derived from motion capture data and driven by static optimization was used to calculate Achilles tendon and patellofemoral joint forces during stance for each speed. Functional regression models were used to estimate the associations of each of nine sensor-measured gait metrics with internal forces across stance, after adjusting for body mass and running speed. RESULTS: At both the Achilles tendon and the patellofemoral joint, cadence, vertical oscillation, and vertical ratio (vertical oscillation divided by step length) showed the strongest associations with internal forces (maximum of 0.4-0.6 BW change in force per one standard deviation change in the gait metric). Other wearable sensor-measured gait metrics, including stance time, leg stiffness, and stance time percent showed weaker associations (<0.4 BW change in force per one standard deviation change in the gait metric). CONCLUSIONS: Runners with higher-than-average cadence, vertical oscillation, or vertical ratio values experience marked differences in internal forces at the Achilles tendon and patellofemoral joint. Of these gait metrics, cadence is the most practical for out-of-lab use because of its ease of accurate measurement with consumer-grade devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Biomechanical Signature of Elite Distance Running: A Matched Pairs Analysis Across Multiple SpeedsScandinavian Journal of Medicine & Science in Sports · 2026
- Biomechanical Responses to Level, Uphill, and Downhill Running Segments During an Outdoor MarathonEuropean Journal of Sport Science · 2026
- Estimating running economy using wearable trunk accelerometry: a comparative analysis of three footwear conditions in highly trained runners.Sports biomechanics · 2026
- Foot Strike Patterns During a Continuous 1600 m Outdoor Run in Recreational Female Runners.Sports (Basel, Switzerland) · 2026
- Influence of outdoor running surface type on loading rate and lower-limb kinematicsBMC Sports Science, Medicine and Rehabilitation · 2026
- A Wearable Pressure-Sensor-Based System for Gait Cycle Analysis: Evaluation and Preliminary Clinical Assessment.Medical engineering & physics · 2026