Accuracy in Step Counting Is Not Accuracy in Quantifying Walking Activity: A Criterion Validity Study of Wearable Devices Under Free-Living Conditions.
Adrien Chanteau, Germain Faity, Guillaume Mahe, Alexis Le Faucheur
Univ Rennes, M2S (Laboratoire Mouvement, Sport, Santé), F-35000 Rennes, France.
Key points
From the paper's conclusion- The level of step-count accuracy obtained from wearable devices did not translate into a comparable level of accuracy in quantifying real-world walking activity. Overall, activPAL, StepWatch, ActiGraph hip/1s and ActiGraph wrist-StepCount showed the most consistent performance. These findings can help researchers select step-based methods that more accurately capture real-world walking patterns.
Abstract
PURPOSE: To determine the criterion validity of research- and consumer-grade wearables (18 step-based methods) for quantifying step counts and step-derived walking metrics in free-living conditions. METHODS: Sixty healthy adults (20-80 years, balanced by sex and decade) wore six monitors for seven days: StepWatch (ankle), activPAL (thigh), ActiGraph (hip and wrist), Fitbit Inspire 2 (hip), Fitbit Charge 5 (wrist), and Garmin Vívoactive 4S (wrist), while wearing a waist-mounted video camera at their discretion during free-living sessions. Step counts from all devices were used to derive metrics of bout duration, frequency, and intensity. Raw ActiGraph data were also processed using five wrist-based machine-learning models for step detection. Video-identified steps labeled by trained researchers served as the criterion. Equivalence testing was performed using a ±10% equivalence margin. RESULTS: Fifty-six participants provided 150 hours of valid video and 10,194 walking bouts. Only StepWatch fell within the equivalence margin for step counts with a mean absolute percent error (MAPE) <10%, with seven additional methods at 10-20%. For total walking bout duration, only activPAL and ActiGraph wrist-StepCount met equivalence criteria; activPAL achieved MAPE <10% and five others at 10-20%. No method met equivalence for the number of walking bouts, with MAPE >20% and balanced accuracy in bout detection <50%. For time spent in moderate-to-vigorous physical activity, activPAL (18.6%) and StepWatch (16.2%) achieved MAPE <20%, but no methods met equivalence. CONCLUSIONS: The level of step-count accuracy obtained from wearable devices did not translate into a comparable level of accuracy in quantifying real-world walking activity. Overall, activPAL, StepWatch, ActiGraph hip/1s and ActiGraph wrist-StepCount showed the most consistent performance. These findings can help researchers select step-based methods that more accurately capture real-world walking patterns.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Criterion Validity of a Consumer Wearable for Step Counting and Activity Intensity Classification in Adults With Lung Cancer: Laboratory-Based Validation Study.JMIR formative research · 2026
- A reproducible pipeline for processing commercial wearable step-count data in aging cohorts: Application and evaluation in the STRRIDE-PD reunion study.Experimental gerontology · 2026
- Digital assessment of real-world walking in people with impaired mobility: How many hours and days are needed?International Journal of Behavioral Nutrition and Physical Activity · 2025
- Advancement in wrist worn physical activity trackers: technological developments and measurement accuracy: a systematic review.Frontiers in digital health · 2026
- Wearable device-based health equivalence of different physical activity intensities against mortality, cardiometabolic disease, and cancerNature Communications · 2025
- Agreement of consumer wearable pulse oximeters across activity conditions and skin pigmentation.Frontiers in digital health · 2026