AAPS PharmSciTech

Practical and Device-Independent Assessment of Spatial and Contrast Resolution in X-ray CT.

Tamaki Miyazaki, Satoshi Iguchi, Kayo Migita, Junichi Sato, Yoshihiro Takeda, Kumiko Kato

Division of Drugs, National Institute of Health Sciences, 3-25-26 Tonomachi, Kawasaki-Ku, Kawasaki, Kanagawa, 210-9501, Japan. miyazaki@nihs.go.jp. · Shimadzu Corporation, 1 Nishinokyo Kuwabara-Cho, Nakagyo-Ku, Kyoto, Kyoto, 604-8511, Japan.

Key points

From the paper's conclusion
  • This approach provides a practical and device-independent framework for image quality assessment and optimization of quantitative XRCT measurements.

Abstract

Despite the increasing use of quantitative X-ray computed tomography (XRCT) analysis in pharmaceutical research, practical and device-independent approaches for objectively assessing image quality and defining acquisition conditions remain limited. As image quality in industrial XRCT is largely governed by spatial and contrast resolution, reliable evaluation of these parameters is essential. In this study, a systematic approach was developed for assessing these parameters in XRCT systems commonly used in pharmaceutical research. Most pharmaceutical materials exhibit low X-ray attenuation and limited intrinsic contrast, making reliable assessment of contrast resolution particularly important for quantitative image analysis. Readily available polymer monofilaments and light metal rods were used to evaluate spatial resolution by the 10-90% distance and contrast resolution by the contrast-to-noise ratio (CNR). The 10-90% distance was strongly dependent on CNR and converged to approximately 4-6 times the nominal pixel size with increasing CNR, regardless of imaging system, acquisition conditions, and sample material. Stable and robust spatial resolution measurements required a CNR of approximately 4 or greater. A separation index describing histogram peak separation was highly correlated with CNR (r = 0.9998) across all experimental conditions. Because CNR was proportional to the square root of effective exposure, the proposed approach enabled prediction of the acquisition conditions to achieve a target image quality level. This approach provides a practical and device-independent framework for image quality assessment and optimization of quantitative XRCT measurements.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Practical and Device-Independent Assessment of Spatial and Contrast Resolution in X-ray CT — Science Skim