Comparison of joint laxity measured using 60- and 80-N distraction forces and manual stress during robot-assisted total knee arthroplasty.
Hiroshi Inui, Haruhiko Nakamura, Ryota Takei, Masaki Uchida, Kei Satou, Tetsu Yamashita, Risa Matsumoto
Department of Orthopaedic Surgery, Saitama Medical University, Kawagoe City, Saitama, 350-8500, Japan. hiroshi_inu0707@yahoo.co.jp. · Department of Orthopaedic Surgery, Saitama Medical University, Kawagoe City, Saitama, 350-8500, Japan.
Key points
From the paper's conclusion- Conclusions The differences between joint laxity measured under manual stress and that measured using a tensioner device varied depending on the compartment and knee flexion angle.
Abstract
BACKGROUND: Appropriate intraoperative soft-tissue balance is essential for achieving successful outcomes following total knee arthroplasty (TKA). However, the optimal distraction force for evaluating joint laxity remains unclear. This study aimed to compare joint laxities measured using specific distraction forces with those obtained under manual varus-valgus stress and assess the interobserver variability. METHODS: A total of 55 bi-cruciate-stabilized TKAs were performed using a robotic system. Medial and lateral joint laxities were evaluated using a force-controlled tensioner device under a distraction force of 60 and 80 N at 10°, 30°, 60°, and 90° of flexion and under manual varus-valgus stress using the robotic system. To assess interobserver differences, all measurements were performed independently by the senior surgeon and one of the assistant surgeons. RESULTS: In the medial compartment, no statistically significant differences were detected between joint laxity under manual stress and that measured using a distraction force of 80 N at 10° and 30° of flexion. At 90° of flexion, no statistically significant difference was detected between JLR and JLT60N. In the lateral compartment, no statistically significant differences were detected between joint laxity under manual stress and that measured using 80 N at 10° and 90° of flexion, whereas joint laxity under manual stress was significantly greater than that measured using 80 N at 30° and 60° of flexion. Interobserver variability was greater in the lateral compartment than in the medial compartment, especially at higher flexion angles. CONCLUSIONS: The differences between joint laxity measured under manual stress and that measured using a tensioner device varied depending on the compartment and knee flexion angle. The lateral compartment showed greater measurement variability, suggesting the need for careful assessment and standardization of intraoperative joint laxity evaluation during robot-assisted TKA.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Mediolateral Joint Balance Assessment Is Reproducible Between Surgeons, Under No Standardized Varus-Valgus Stress, During Robot-Assisted Total Knee Arthroplasty.Journal of clinical medicine · 2026
- Greater valgus severity is associated with larger lateral flexion-gap changes between intraoperative assessments during robot-assisted total knee arthroplasty: A retrospective cohort study.Journal of experimental orthopaedics · 2026
- Objective Quantification of Soft-Tissue Balance in Total Knee Arthroplasty: Expanded Validation of the Pendulum Knee Drop Test Across Multiple Surgeons.The journal of knee surgery · 2026
- Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study.Journal of clinical medicine · 2026
- Preresection hyperextension is associated with greater initial extension laxity and site-specific reductions in bone resection without substantial joint-line lowering in robot-assisted cruciate-retaining total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026
- Femoral rotation and medial flexion gap tightness in functional alignment robotic total knee arthroplasty for varus kneesJournal of Robotic Surgery · 2026