Intraoperative aneurysm sac embolization using an N-butyl-2-cyanoacrylate-Lipiodol-ethanol mixture during emergency endovascular repair of ruptured abdominal aortic aneurysm: initial clinical experience.
Koki Ikebata, Manabu Misu, Masayoshi Waga, Takashi Hashimoto, Hiroaki Kaneyama, Kiyoshi Koizumi, Kenichi Hashizume, Hideyuki Shimizu
Department of Cardiovascular Surgery, Ashikaga Red Cross Hospital, 284-1 Yobe-Cho, Ashikaga, Tochigi, 326-0843, Japan. koki.lakeside@gmail.com. · Department of Radiology, Ashikaga Red Cross Hospital, 284-1 Yobe-Cho, Ashikaga, Tochigi, 326-0843, Japan.
Key points
From the paper's conclusion- Intraoperative aneurysm sac embolization with the N-butyl-2-cyanoacrylate-Lipiodol-ethanol mixture was technically feasible during emergency endovascular repair, and its handling characteristics permitted controlled injection through a jailed microcatheter. Whether the mixture improves rupture-site sealing, prevents type II endoleak, or promotes sac regression remains to be established, and displacement of the cast warrants imaging surveillance.
Abstract
PURPOSE: Endovascular aneurysm repair for ruptured abdominal aortic aneurysm leaves the rupture site untreated, and in rupture-associated coagulopathy, retrograde sac perfusion may sustain life-threatening hemorrhage. A mixture of N-butyl-2-cyanoacrylate, Lipiodol, and ethanol is a liquid embolic material reported experimentally to be less adhesive than N-butyl-2-cyanoacrylate-Lipiodol mixtures. We report our initial experience with this mixture for aneurysm sac embolization in this setting. MATERIALS AND METHODS: Four consecutive male patients (aged 72-82 years) underwent emergency endovascular repair of ruptured infrarenal abdominal aortic aneurysm with intraoperative sac embolization between October 2022 and July 2023, after introduction of the technique. Aneurysm diameter was 53-68 mm, Fitzgerald class was III in three patients and IV in one, and two were in shock on arrival. After stent-graft deployment over a guidewire jailed within the sac, sac angiography was performed in three patients and was precluded by re-rupture in one. Aortography excluded type Ia endoleak, and 5-7 mL of the mixture (N-butyl-2-cyanoacrylate:Lipiodol:ethanol 1:5:1 in three patients, 2:3:1 in one) was injected through the jailed microcatheter until the residual perigraft cavity, including the rupture site, was opacified. RESULTS: Sac angiography showed extravasation at the rupture site in one of the three patients examined, and aortography before embolization showed a type II endoleak in two. The indications were thus extravasation with type II endoleak, type II endoleak alone, prophylaxis, and intraoperative re-rupture in one patient each. Delivery was successful in all patients without catheter adhesion or non-target embolization. Three patients survived without postoperative transfusion. The endoleaks seen before embolization were absent on day-1 CT. No endoleak was detected on contrast-enhanced CT during follow-up of 35 months in two patients and 24 months in one, whose later CT was unenhanced. The sac diameter remained below baseline at 35-36 months without reintervention. In two survivors, part of the cast lay outside the sac, having passed through the rupture site during injection in one and by delayed displacement in the other. This adverse imaging finding remained stable after 3 months and caused no clinical sequelae. One patient with intraoperative re-rupture died of hemorrhagic shock on the day of surgery. CONCLUSION: Intraoperative aneurysm sac embolization with the N-butyl-2-cyanoacrylate-Lipiodol-ethanol mixture was technically feasible during emergency endovascular repair, and its handling characteristics permitted controlled injection through a jailed microcatheter. Whether the mixture improves rupture-site sealing, prevents type II endoleak, or promotes sac regression remains to be established, and displacement of the cast warrants imaging surveillance.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Endovascular adhesive repair using N-butyl cyanoacrylate for spontaneous dissecting aneurysms of the celiac and hepatic arteries: technique and long-term outcomes.CVIR endovascular · 2026
- Ruptured INfrarenal abdominal AneurySm: aortiC repair using the ENduranT Endograft. The R.IN.AS.C.ENT.E. Study.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
- N-Butyl Cyanoacrylate Use for the Management of Type II Endoleak in Endovascular Aortic Repair: A Scoping Review.Journal of clinical medicine · 2026
- Emergency Endovascular Repair of a Large Ruptured Isolated Internal Iliac Artery Aneurysm in a 98-Year-Old Patient: A Case Report.Journal of clinical medicine · 2026
- Case Report: Successful Management of a Ruptured Abdominal Aortic Aneurysm With Concurrent Acute Myocardial Infarction in an 84-Year-Old Male.Clinical case reports · 2026
- Percutaneous and Endovascular Embolization-Based Treatments of Type 1A and Type 1B Endoleaks after Endovascular Aneurysm Repair.Vascular and endovascular surgery · 2026