Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists

Ruptured INfrarenal abdominal AneurySm: aortiC repair using the ENduranT Endograft. The R.IN.AS.C.ENT.E. Study.

Antonio Lorido, Domenico Mirabella, Bernardo Orellana, Emiliano Chisci, Andrea Esposito, Fabrizio Chegai, Ettore Dinoto, Giulio Accarino,

Vascular Surgery, ASL Viterbo, PO Santa Rosa, Viterbo, Italy. · Vascular Surgery Unit, Azienda Ospedaliera Universitaria Policlinico "P. Giaccone," Palermo, Italy.

Observational · n=121

Key points

From the paper's conclusion
  • In this large, strictly defined infrarenal rAAA cohort, bifurcated Endurant stent grafts demonstrated high technical success and favorable early and mid-term clinical outcomes, including in patients with hostile neck anatomy. Early identification and management of ACS and judicious use of AOBs may improve survival. These findings reinforce current EVAR-first guidelines and emphasize the importance of device-specific outcome assessment in emergent rAAA repair.Clinical ImpactThis multicenter study provides one of the largest device-specific evaluations of bifurcated Endurant stent grafts for infrarenal ruptured abdominal aortic aneurysms in a rigorously defined Italian cohort, demonstrating high technical success (96.7%) and low 30-day mortality (15.7%) despite a high prevalence of hostile neck anatomy (54.5%). Abdominal compartment syndrome and the use of an aortic occlusion balloon emerged as independent predictors of early mortality, highlighting the critical role of perioperative management. Mid-term outcomes were favorable, with a 5-year survival rate of 65.4%, a low incidence of type Ia endoleak (2.5%), and high freedom from reintervention (91.6%). Overall, these findings support the use of Endurant devices in emergent settings for anatomically suitable patients and reinforce EVAR-first strategies in the management of ruptured abdominal aortic aneurysms.

Abstract

BACKGROUND: Ruptured abdominal aortic aneurysm (rAAA) represents a vascular surgical emergency with high mortality. Endovascular aneurysm repair (EVAR) using the bifurcated Endurant stent graft system is widely employed; however, data specifically addressing its performance in infrarenal rAAA remain limited. METHODS: We conducted a retrospective, multicenter study including 121 patients with confirmed infrarenal rAAA treated exclusively with bifurcated Endurant II or IIs (Medtronic Inc., Minneapolis, Minnesota) devices across 5 Italian tertiary vascular centers from January 2014 to October 2024. Primary endpoints were technical success and 30-day all-cause mortality. Secondary outcomes included long-term survival, incidence of endoleaks, and reintervention rates. Patients receiving alternative stent grafts or hybrid procedures were excluded to ensure cohort homogeneity. RESULTS: A total of 121 patients were enrolled during the study period. The cohort had a mean age of 75.3 ± 8.2 years, with 91.7% male predominance. Technical success was achieved in 96.7%. The 30-day mortality rate was 15.7%. Multivariate logistic regression identified abdominal compartment syndrome (ACS) (odds ratio [OR], 29.8; 95% confidence interval [CI], 2.8-317.7; P = .005) and use of an aortic occlusion balloon (AOB) (OR, 16.4; 95% CI, 2.5-106.2; P = .003) as independent predictors of early mortality. At a median follow-up of 33.6 months (interquartile range, 4.9-72.3), 5-year survival was 65.4%, freedom from any endoleak was 92.6%, and freedom from reintervention was 91.6%. Late type Ia endoleaks occurred in 2.5% of patients. CONCLUSIONS: In this large, strictly defined infrarenal rAAA cohort, bifurcated Endurant stent grafts demonstrated high technical success and favorable early and mid-term clinical outcomes, including in patients with hostile neck anatomy. Early identification and management of ACS and judicious use of AOBs may improve survival. These findings reinforce current EVAR-first guidelines and emphasize the importance of device-specific outcome assessment in emergent rAAA repair.Clinical ImpactThis multicenter study provides one of the largest device-specific evaluations of bifurcated Endurant stent grafts for infrarenal ruptured abdominal aortic aneurysms in a rigorously defined Italian cohort, demonstrating high technical success (96.7%) and low 30-day mortality (15.7%) despite a high prevalence of hostile neck anatomy (54.5%). Abdominal compartment syndrome and the use of an aortic occlusion balloon emerged as independent predictors of early mortality, highlighting the critical role of perioperative management. Mid-term outcomes were favorable, with a 5-year survival rate of 65.4%, a low incidence of type Ia endoleak (2.5%), and high freedom from reintervention (91.6%). Overall, these findings support the use of Endurant devices in emergent settings for anatomically suitable patients and reinforce EVAR-first strategies in the management of ruptured abdominal aortic aneurysms.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers