International journal of retina and vitreous

Scleral buckling under a slit-lamp illumination system in patients with primary rhegmatogenous retinal detachment.

Vasileia Chatzistergiou, Boris Marguier, Pierre Negrier, Aude Couturier, Elise Philippakis

Ophthalmology Department, Université Paris Cité, AP-HP, Hôpital Lariboisière, 2 Rue Ambroise Paré, Paris, 75010, France. · Ophthalmology Department, Université Paris Cité, AP-HP, Hôpital Lariboisière, 2 Rue Ambroise Paré, Paris, 75010, France. elise.philippakis@gmail.com.

Observational · n=46

Key points

From the paper's conclusion
  • Scleral buckling using a surgical microscope with an integrated slit-lamp and a wide-angle contact lens is a feasible technique associated with satisfactory anatomical and functional outcomes. This approach was associated with a high single-surgery success rate and a manageable complication rate.

Abstract

PURPOSE: To present the slit-lamp illumination and visualisation system for scleral buckling for primary rhegmatogenous retinal detachment (RRD) and assess its feasibility and postoperative outcomes. METHODS: In a retrospective, single-center, non-comparative case series, patients with subtotal RRD who underwent scleral buckling under a slit-lamp illumination system at Lariboisière Hospital, between May 2017 and May 2022, were included. Patients who underwent scleral buckling combined with vitrectomy, with a history of retinal surgery and with maculopathies interfering with visual acuity were excluded. The following preoperative data were collected: best-corrected visual acuity (BCVA), number and location of retinal breaks, extend of the detachment, presence of macular detachment. The fundus was visualised using a quadraspheric lens, and the slit-lamp system integrated in the surgical microscope. Anatomical success rate, BCVA improvement and complications were collected. RESULTS: Forty-six eyes of 46 patients with a mean age of 43.2 ± 12.8 years, followed for 8.7 ± 8.3 months were included. No procedure was switched to vitrectomy during surgery. The single surgery success rate was 93.5% (43 eyes). Three eyes had to undergo vitrectomy due to vitreoretinal proliferation. BCVA improved from 0.63 ± 0.76 LogMAR (Snellen 20/80) before surgery to 0.33 ± 0.40 LogMAR (Snellen 20/40) after surgery (p=0.002). Intraoperative and postoperative complications were experienced by two and nine patients, respectively. CONCLUSION: Scleral buckling using a surgical microscope with an integrated slit-lamp and a wide-angle contact lens is a feasible technique associated with satisfactory anatomical and functional outcomes. This approach was associated with a high single-surgery success rate and a manageable complication rate. CLINICAL TRIAL NUMBER: Not applicable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers