Scleral buckling under a slit-lamp illumination system in patients with primary rhegmatogenous retinal detachment.
Vasileia Chatzistergiou, Boris Marguier, Pierre Negrier, Aude Couturier, Elise Philippakis
Ophthalmology Department, Université Paris Cité, AP-HP, Hôpital Lariboisière, 2 Rue Ambroise Paré, Paris, 75010, France. · Ophthalmology Department, Université Paris Cité, AP-HP, Hôpital Lariboisière, 2 Rue Ambroise Paré, Paris, 75010, France. elise.philippakis@gmail.com.
Key points
From the paper's conclusion- Scleral buckling using a surgical microscope with an integrated slit-lamp and a wide-angle contact lens is a feasible technique associated with satisfactory anatomical and functional outcomes. This approach was associated with a high single-surgery success rate and a manageable complication rate.
Abstract
PURPOSE: To present the slit-lamp illumination and visualisation system for scleral buckling for primary rhegmatogenous retinal detachment (RRD) and assess its feasibility and postoperative outcomes. METHODS: In a retrospective, single-center, non-comparative case series, patients with subtotal RRD who underwent scleral buckling under a slit-lamp illumination system at Lariboisière Hospital, between May 2017 and May 2022, were included. Patients who underwent scleral buckling combined with vitrectomy, with a history of retinal surgery and with maculopathies interfering with visual acuity were excluded. The following preoperative data were collected: best-corrected visual acuity (BCVA), number and location of retinal breaks, extend of the detachment, presence of macular detachment. The fundus was visualised using a quadraspheric lens, and the slit-lamp system integrated in the surgical microscope. Anatomical success rate, BCVA improvement and complications were collected. RESULTS: Forty-six eyes of 46 patients with a mean age of 43.2 ± 12.8 years, followed for 8.7 ± 8.3 months were included. No procedure was switched to vitrectomy during surgery. The single surgery success rate was 93.5% (43 eyes). Three eyes had to undergo vitrectomy due to vitreoretinal proliferation. BCVA improved from 0.63 ± 0.76 LogMAR (Snellen 20/80) before surgery to 0.33 ± 0.40 LogMAR (Snellen 20/40) after surgery (p=0.002). Intraoperative and postoperative complications were experienced by two and nine patients, respectively. CONCLUSION: Scleral buckling using a surgical microscope with an integrated slit-lamp and a wide-angle contact lens is a feasible technique associated with satisfactory anatomical and functional outcomes. This approach was associated with a high single-surgery success rate and a manageable complication rate. CLINICAL TRIAL NUMBER: Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Additive benefit of scleral buckling in primary rhegmatogenous retinal detachment repair with silicone oil.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
- Encircling band without retinopexy in Sub-Saharan African patients with primary retinal detachment, unvisualized breaks, and no posterior vitreous detachment.Journal francais d'ophtalmologie · 2026
- Anatomical and Functional Outcomes of Repeat Vitrectomy Combined with Encircling Scleral Buckling for First Recurrent Rhegmatogenous Retinal Detachment After Primary Vitrectomy: A Retrospective Cohort Study.Journal of clinical medicine · 2026
- Long-term anatomical and visual outcomes following scleral buckling for stage 4 retinopathy of prematurity: Revisiting the basics.Journal francais d'ophtalmologie · 2026
- Clinical outcomes of repositioning subluxated in-the-bag intraocular lenses using the flanged belt-loop technique with 6-0 polypropyleneJournal of Cataract & Refractive Surgery · 2025
- A Novel Intraocular Lens and Capsular Bag Complex Suspension Technique for Repositioning Late In-the-Bag Intraocular Lens Dislocation.Clinical ophthalmology (Auckland, N.Z.) · 2026