Effect of 3D superimposition software on intraoral scanner accuracy and monitoring outcome.
Albert Mehl, Jenny Buhl, Andreas Ender
Division of Computerized Restorative Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland. · Division of Computerized Restorative Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland. jenny.buhl@zzm.uzh.ch.
Key points
From the paper's conclusion- Evaluation software is a significant source of variability in 3D deviation metrics; Control X produced consistently higher (more conservative) quantile‑range values, particularly for Q95_Q05_half.
Abstract
OBJECTIVES: To determine whether 3D superimposition software ("Apps") systematically affects 3D deviation outcomes derived from intraoral scanner (IOS) data, using two quantile‑range accuracy metrics (Q90_Q10_half and Q95_Q05_half). MATERIALS AND METHODS: Two jaw‑sized reference models were digitized with a high‑resolution optical scanner (ATOS III) to generate reference STL meshes (REF_STL). Five IOS devices acquired ten scans per device and per jaw model, exported as STL meshes (IMP_STL): Emerald Green, iTero 5D, Medit i900, Primescan, and Trios 5. Each IMP_STL was trimmed (1 mm above gingival line) and superimposed to REF_STL in four Apps: commercial industrial software: Geomagic Control X and GOM Inspect, and open dentistry-focused software Medit Design (Compare) and Dentexion; resulting in total to N = 400 superimpositions. For each superimposition, Q90_Q10_half and Q95_Q05_half values were computed from point-wise signed surface distances. A linear mixed‑effects model tested factor App as fixed effect with random intercepts for factors Device and Jaw, followed by Bonferroni‑adjusted pairwise comparisons (α = 0.05). RESULTS: App significantly influenced Q90_Q10_half (p < 0.01) and Q95_Q05_half (p < 0.001). Control X yielded higher adjusted means than Dentexion and Compare for Q90_Q10_half (both p < 0.01), while Dentexion, GOM, and Compare did not differ. For Q95_Q05_half, Control X exceeded all other Apps (all p < 0.01). Notably, IOS rankings were stable across Apps, indicating that software altered magnitude but not relative ordering. CONCLUSIONS: Evaluation software is a significant source of variability in 3D deviation metrics; Control X produced consistently higher (more conservative) quantile‑range values, particularly for Q95_Q05_half. CLINICAL RELEVANCE: Inter‑study comparisons in digital accuracy research should report the evaluation software and settings. Dentistry‑focused Apps (e.g., with automated tooth segmentation) may reduce operator‑dependent effects and facilitate clinically applicable monitoring.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Agreement and reproducibility of intraoral scan- versus CBCT-based three-dimensional implant position assessment in the posterior mandible - a paired in vitro method-comparison study.International journal of implant dentistry · 2026
- Limitations of RMS error in evaluating intraoral scanner accuracy: Comparison with linear and angular distortions from an enhanced metrology protocol.The Journal of prosthetic dentistry · 2026
- Effect of implant angulation on the trueness and precision of intraoral scanning and photogrammetryBMC Oral Health · 2025
- Capturing of interdental areas with digital and conventional impression systems and their impact on automatic tooth segmentation in CAD software: an in vitro study.Clinical oral investigations · 2026
- Comparative Evaluation of Tooth Type and Pulp Chamber Depth on the Accuracy of Endocrown Scans Acquired Using Various Intraoral Scanners.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2026
- Optimizing Digital Impressions: A Review of Factors Affecting Intraoral Scanner Accuracy.Diagnostics (Basel, Switzerland) · 2026