EJNMMI Physics

Defeating the Black Knight: a focused review of cardiac PET/MRI motion correction

Heeseung Lim, Benjamin Wilk, Gerald Moran, David Faul, Jonathan D. Thiessen, Frank S. Prato

Review

Key points

From the paper's conclusion
  • Keywords: Review, PET/MRI, Motion Correction, Cardiac, Machine Learning

Abstract

To achieve high resolution and quantifiable cardiac Positron Emission Tomography (PET) images, the significant challenge of independent and highly variable respiratory and cardiac motion must be overcome. These motions often exceed the thickness of the left ventricular (LV) wall, blurring images and hindering the accurate diagnosis and quantification of cardiac diseases. While Magnetic Resonance Imaging (MRI) currently excels at resolving transmural differences in the LV wall, a capability not yet fully achieved by PET, advancements in PET resolution are now approaching 3 mm. This suggests that transmural quantification is attainable if motion is effectively mitigated. Hybrid PET/MRI systems offer a synergistic solution by providing simultaneous, co-registered data, allowing MRI’s superior anatomical resolution to guide PET reconstruction. This integration allows for motion correction and enhanced spatial resolution without the severe signal to noise ratio reduction associated with traditional gating methods. Strategies for defeating motion include using MRI derived motion vectors from Cine MRI and applying them to PET data, which significantly improves image quality. Furthermore, the integration of anatomical priors from MRI into PET reconstruction offers further resolution enhancement, particularly for the thin heart walls. The transformative potential of machine learning can further accelerate these corrections, paving the way for advanced applications like multi-tracer injection studies. Overcoming cardiac motion in PET/MRI promises to profoundly impact the diagnosis and management of heart disease by providing the quantifiable, high resolution cardiac PET images necessary for preclinical research and precise clinical theranostic assessment. Keywords: Review, PET/MRI, Motion Correction, Cardiac, Machine Learning

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Defeating the Black Knight: a focused review of cardiac PET/MRI motion correction — Science Skim