Investigation of CardioFreeze Motion Correction for Cardiac PET/CT.
Ashley R Wang, Liang Guo, Ramesh Fazzone-Chettiar, Christopher A Weyman, Charles Hayden, Bruce Spottiswoode, Stephanie Thorn, Yi-Hwa Liu,
Section of Cardiovascular Medicine, Department of Internal Medicine, Yale School of Medicine, New Haven, CT, USA. · Department of Biomedical Engineering, Yale School of Medicine, New Haven, CT, USA.
Key points
From the paper's conclusion- Over 1/3 of patients undergoing cardiac PET/CT have detectible motion leading to potential artifacts with clinical significance. Cardiac and respiratory motion correction improves image quality and may improve diagnostic accuracy, particularly when respiratory motion is severe. Further studies are critical to investigate the clinical impacts of improved image quality.
Abstract
BACKGROUND: Cardiac imaging with positron emission tomography and computed tomography (PET/CT) is a principal technique in the diagnosis and prognostication of coronary artery disease. PET/CT image quality can be negatively impacted by patient, cardiac, and respiratory motion. METHODS: We evaluated images from 102 patients clinically referred for cardiac rest/stress Rb-82 PET/CT myocardial perfusion imaging. Patient images were processed with a prototype data-driven motion detection algorithm and stratified by motion severity. Images were subjected to cardiac (CS) or cardiac and respiratory (CD) motion correction via a novel reconstruction tool. Validated image quality markers including target-to-background ratio (TBR) were assessed between corrected and non-corrected images and analyzed via student's t-tests. RESULTS: The motion detection algorithm identified 36 (35.3%) patients with significant motion. Image processing via CS yielded a statistically significant increase in mean image contrast (TBR 3.65±0.07, p<0.01) and intensified when respiratory motion correction was applied (3.78±0.07, p<0.005). Motion correction is more effective when applied to images containing greater motion, improving mean TBR by 3% (p<0.05) in non-motion scans but >10% (p<0.01) in significant motion cases. Three months post-imaging, 18 patients underwent clinically indicated coronary angiography: seven patients demonstrated significant motion, and CD motion correction improved their image quality to that of patients with no motion. CONCLUSIONS: Over 1/3 of patients undergoing cardiac PET/CT have detectible motion leading to potential artifacts with clinical significance. Cardiac and respiratory motion correction improves image quality and may improve diagnostic accuracy, particularly when respiratory motion is severe. Further studies are critical to investigate the clinical impacts of improved image quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of a motion-correction algorithm on motion-related image quality in mid-diastolic CCTA using 320-detector row CT.Journal of cardiovascular computed tomography · 2026
- The Effect of Motion Correction on Quantitative Perfusion Indices and Threshold-Based Interpretation in 13N-Ammonia Dynamic PET Myocardial Perfusion Imaging.Diagnostics (Basel, Switzerland) · 2026
- Motion correction algorithm improves right coronary artery image quality at heart rates > 75 bpm in non-ECG-gated coronary CT angiography.Journal of applied clinical medical physics · 2026
- Improved Visualization of Heart Valves With 4D-CT Using a Novel Motion Correction Algorithm.Investigative radiology · 2026
- Defeating the Black Knight: a focused review of cardiac PET/MRI motion correctionEJNMMI Physics · 2026
- Three-dimensional image metric maps for characterizing local image changes associated with AI-based motion correction in coronary CT.Radiological physics and technology · 2026