Variable-specific preprocessing enables cross-scale transferable Raman models from high-throughput bioreactor data.
Sung-Hyuk Han, Jiyun Park, Kwang-Bae Lee, Cheol-Hwan Park, Dong-Yup Lee
Upstream Process Engineering, Manufacturing Science & Technology, R&D, GC Biopharma, 93 Ihyun-ro, 30beon-gil, Giheung-gu, Yongin, Gyeonggi-do, 16924, Republic of Korea. shhan85@gccorp.com. · Upstream Process Engineering, Manufacturing Science & Technology, R&D, GC Biopharma, 93 Ihyun-ro, 30beon-gil, Giheung-gu, Yongin, Gyeonggi-do, 16924, Republic of Korea.
Key points
From the paper's conclusion- These findings suggest that intelligent preprocessing selection can mitigate out-of-distribution effects in Raman chemometric models and enable more reliable prediction across scales using HT datasets for model calibration.
Abstract
Raman spectroscopy is increasingly used as a process analytical technology (PAT) for real-time monitoring of bioprocesses. However, chemometric models developed using high-throughput (HT) mini-bioreactor systems often show limited predictive performance when applied to larger-scale processes, reflecting an out-of-distribution (OOD) challenge in cross-scale model transfer. In this study, we investigated whether variable-specific data preprocessing strategies can improve the cross-scale prediction performance of Raman chemometric models calibrated using HT cell culture data. Multiple preprocessing approaches were systematically evaluated for key cell culture target outputs, and the optimal preprocessing pipeline for each output was selected based on its ability to minimize cross-scale prediction error. The optimized variable-specific preprocessing pipelines reduced cross-scale prediction errors by 14.0-56.1% in RMSEP across the five initially poorly transferable target outputs compared with the standard single-scale preprocessing pipeline. Consequently, these optimized single-scale models achieved predictive accuracy approaching that of resource-intensive combined-scale models. Importantly, the improvement was not dependent on a specific preprocessing technique but rather on selecting preprocessing strategies suited to the spectral characteristics of each target output. These findings suggest that intelligent preprocessing selection can mitigate out-of-distribution effects in Raman chemometric models and enable more reliable prediction across scales using HT datasets for model calibration. This approach highlights the potential of Raman spectroscopy as a practical and scalable PAT tool for industrial bioprocess development.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Balancing Prediction Performance and Spectral Interpretability: Multimetric Guided Design of Raman Spectrum Preprocessing Pipelines to Transfer Single Compound Models to Bioprocess DataJournal of Raman Spectroscopy · 2026
- Raman-guided sample subset selection for cost-efficient offline calibration in bioprocesses.Bioprocess and biosystems engineering · 2026
- Enabling Raman Spectroscopy-Based Cell Culture Process Control via Real-Time Chemometric Model Calibration.Biotechnology and bioengineering · 2026
- Machine Learning-Enhanced Generic Raman Model for Commercial-Scale Cell Culture Process Monitoring.Biotechnology journal · 2026
- SIM-CaliRam: A workflow combining simulation-informed references and biomass-augmented features for in-line Raman calibration of Saccharomyces cerevisiae.Biotechnology progress · 2026
- Rapid development of a transferable R aman model using high‐throughput cell culture for monitoring monoclonal antibody titerBiotechnology Progress · 2026