SIM-CaliRam: A workflow combining simulation-informed references and biomass-augmented features for in-line Raman calibration of Saccharomyces cerevisiae.
Terrance Wilms, Steffi Knorn
Chair of Control, Institute of Chemical and Process Engineering, Technische Universität Berlin, Berlin, Germany.
Key points
From the paper's conclusion- These results support target-specific model selection rather than a universal calibration pipeline.
Abstract
Raman spectroscopy is a promising in-situ Process Analytical Technology for upstream bioprocesses, but transferring trained calibration models to new, independent fermentation runs without re-calibration remains a challenge due to sparse sample references (SaR) and prediction drift caused by biomass-induced fluorescence and turbidity effects. We present SIM-CaliRam, a calibration workflow combining two physically motivated interventions. First, Simulation-Informed References (SiR) densify glucose, ammonium, and phosphate labels using a feed-driven, non-reactive mass balance on a dedicated uninoculated non-reactive feed run, where substrate dynamics are determined by feeding and dilution. SiR labels agreed closely with the SaR values. Additionally, Biomass-augmented Feature (BaF) appends Raman-predicted biomass as an additional substrate-model regressor, providing a proxy for residual biomass-induced spectral confounding in the feature space. The workflow is demonstrated on Saccharomyces cerevisiae fermentations and evaluated within a systematic grid-search over established preprocessing options and six calibration methods spanning linear, Bayesian nonparametric, and neural network approaches. Conventional SaR calibration serves as the baseline. Training uses two AV runs, with model selection on a separate CV run and final evaluation on a held-out TEST run. The best selected models achieve NRMSETEST of 0.203 (biomass, SaR), 0.206 (glucose, SiR), 0.350 (ammonium, SiR + BaF), and 0.598 (phosphate, SiR). SiR improved phosphate prediction (R2 = 0.64) relative to SaR (R2 = -1.2), although the remaining prediction error limits standalone process-control application. Selected preprocessing, learner, and augmentation configurations differed across analytes. These results support target-specific model selection rather than a universal calibration pipeline.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Raman-guided sample subset selection for cost-efficient offline calibration in bioprocesses.Bioprocess and biosystems engineering · 2026
- Balancing Prediction Performance and Spectral Interpretability: Multimetric Guided Design of Raman Spectrum Preprocessing Pipelines to Transfer Single Compound Models to Bioprocess DataJournal of Raman Spectroscopy · 2026
- Variable-specific preprocessing enables cross-scale transferable Raman models from high-throughput bioreactor data.Bioresources and bioprocessing · 2026
- Cross-attention fusion of Raman and NIR spectra for glucose soft sensing in fed-batch fermentation.Bioprocess and biosystems engineering · 2026
- Raman spectroscopic quantification of phycocyanin and process metadata-based data fusion for dry cell weight in Spirulina platensis cultivation.Bioresource technology · 2026
- Machine Learning-Enhanced Generic Raman Model for Commercial-Scale Cell Culture Process Monitoring.Biotechnology journal · 2026