Torque expression in directly printed and thermoformed clear aligners: a controlled in vitro biomechanical comparison of power ridge effects.
Aliaa A Khadre, Mohamed Elkorashie, Mostafa Magdy Elzahar, Christoph Bourauel, Ahmed Mahmoud Fouda
Department of Orthodontics, Suez Canal University, Ismailia, Egypt. · Department of Orthodontics, Suez Canal University, Ismailia, Egypt. mo.elkorashie@dent.suez.edu.eg.
Key points
From the paper's conclusion- Four aligner groups were evaluated: Zendura Flex thermoformed aligners (Bay Materials LLC, USA) with (ZF-PR) and without (ZF-C) power ridges, and two directly printed aligners with power ridges fabricated from TA-28 (Graphy Inc., Seoul, South Korea) and DCA (LuxCreo Inc., Bellevue, WA, USA) resin materials.
Abstract
BACKGROUND: Torque control of anterior teeth remains a major challenge in clear aligner therapy. Power ridges have been introduced to improve buccolingual root control; however, their biomechanical performance in directly printed aligners remains insufficiently investigated. The aim of this study was to compare the torque efficiency of power ridges in thermoformed and directly printed aligners. METHODOLOGY: A controlled in-vitro study was conducted using a standardised maxillary model requiring incisor torque correction. Four aligner groups were evaluated: Zendura Flex thermoformed aligners (Bay Materials LLC, USA) with (ZF-PR) and without (ZF-C) power ridges, and two directly printed aligners with power ridges fabricated from TA-28 (Graphy Inc., Seoul, South Korea) and DCA (LuxCreo Inc., Bellevue, WA, USA) resin materials. Power ridges were digitally positioned on the labial gingival third of the maxillary central incisors. Biomechanical testing was performed using the Orthodontic Measurement and Simulation System (OMSS) to assess torque expression, root displacement, and force-moment systems under controlled temperatures (25 °C and 37 °C). RESULTS: Torque expression demonstrated a clear material-dependent pattern. ZF-C, used as the baseline, showed moderate and consistent torque expression (38-39% of the programmed torque) across temperatures, with no significant temperature-dependent differences. DCA exhibited the highest torque expression, reaching 62% at 25 °C and 47% at 37 °C. ZF-PR showed intermediate performance (32-42%) with moderate temperature-related variation. TA-28 demonstrated the lowest torque expression (10-17%) with no significant temperature effect. Secondary outcomes supported these findings, with moment generation and displacement patterns correlating with torque expression, whereas force magnitude did not. CONCLUSIONS: Torque expression in clear aligner systems is primarily governed by material properties and thermomechanical behaviour. Design features alone cannot fully compensate for limitations in material performance. Effective torque delivery depends on the generation and transmission of an appropriate force-moment system rather than on force magnitude alone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative analysis of experimental torque behavior and physicochemical properties of commercial and in‑house orthodontic aligners.Journal of the World federation of orthodontists · 2026
- Mechanical properties of thermoformed and direct-printed aligner materials after immersion in 37 °C water: a 14-day in vitro studyScientific Reports · 2026
- 3D‑printed modified power ridges for optimized torque control of maxillary incisors in clear aligner treatment: a finite element analysisBMC Oral Health · 2026
- Thirty-Day Thermomechanical Ageing of 3D-Printed and Thermoformed Orthodontic Aligners: A Comparative Force Analysis.International dental journal · 2026
- Fit analysis of 3D-printed versus thermoformed clear aligners for labial tooth movement using micro-CT: an in vitro studyScientific Reports · 2026
- Initial Force Expression of Different Clear Aligner Systems in a Simulated Maxillary Canine Distalization Model with Lateral Incisor Agenesis: An In Vitro Comparative Study.Bioengineering (Basel, Switzerland) · 2026