An 18-month pilot microbiological evaluation of sterilized operating room supplies stored under routine clinical conditions at a single hospital in Japan
Kentaro Hara, Misa Tomooka, Reika Tachibana, Ryosuke Kumashiro
Nagasaki Medical Center · Kumamoto University
Key points
From the paper's conclusion- This study reports a pre-specified 18-month pilot interim analysis of a prospective observational evaluation of ERSM.
Abstract
OBJECTIVE: Time-related sterility maintenance (TRSM) remains common in Japanese operating rooms (ORs), requiring routine re-sterilization of unopened supplies. Event-related sterility maintenance (ERSM), which defines loss of sterility based on contamination events rather than elapsed time, may reduce unnecessary reprocessing and associated burden. This study reports a pre-specified 18-month pilot interim analysis of a prospective observational evaluation of ERSM. RESULTS: This single-center prospective observational study was conducted in a tertiary-care OR. Representative materials (titanium instruments, cotton, and latex) were sterilized using steam, ethylene oxide, or vaporized hydrogen peroxide, double-bagged and heat-sealed in ISO 11607-1–compliant sterile barrier systems, and stored in closed cabinets at three OR locations under routine clinical handling. Sterility testing followed the Japanese Pharmacopoeia (18th edition) sterility test (4.06), harmonized with USP < 71 > and Ph. Eur. 2.6.1. At 18 months, all 18 cultured items showed no microbial growth (0/18) across all sterilization modalities and storage locations. These interim findings are descriptive and suggest feasibility only; the ongoing protocol will continue to the planned 60-month evaluation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Five-year prospective microbiological evaluation of sterilised operating room supplies stored under event-related sterility maintenance conditions: a single-centre study with molecular characterisation of a fungal contaminantJournal of Hospital Infection · 2026
- Environmental, Economic, and Labour Burden of Time-related Sterility Maintenance and the Potential Reductions from Event-related Sterility Maintenance: A Single-Centre Gate-to-Gate Modelling Study.The Journal of hospital infection · 2026
- Expired endoscopic devices remain sterile and functional: an international multicentre study challenging current shelf-life criteria.Endoscopy · 2026
- Identification of key control points in instrument reprocessing of hospital central sterile supply department and its association analysis with surgical site infection.Frontiers in public health · 2026
- From cabinet to PlasmaBag: validating mobile endoscope storage with plasma technology.Microbiology spectrum · 2026
- Level of Knowledge of the Use of Sterilization Equipment Among Final-Year Dental Trainees: A Cross-Sectional Study in a Mexican StateOral · 2026