Optimisation of BTX removal from simulated refinery effluent using hydrophobic DES: a response surface methodology approach
Ugochi Judith Okoduwa, Victor Olatunji Ajibola, Adamu Uzairu, Edith Bolanle Agbaji, Jeffery Tsware Barminas, Cynthia Ujuh Odili, Opeoluwa Olusola Fasanya
Key points
From the paper's conclusion- Within these limits, the HDES shows promise for benzene removal from refinery effluent, although its environmental performance and its stability on reuse were not assessed in this study.
Abstract
Petroleum refining generates effluents rich in monocyclic aromatics with toxic benzene, toluene and xylene (BTX) persisting in water, so their removal is an environmental priority. Here, a hydrophobic deep eutectic solvent (HDES) of tetrabutylammonium bromide and decanoic acid (1:2) was evaluated for liquid-liquid BTX extraction. A four-factor central composite design varied stirring speed, solvent mass fraction, contact time and temperature across 30 runs, analysed by response surface methodology (RSM). Benzene and toluene efficiencies were modelled on a logit scale to keep predictions physically bounded, and xylene on the untransformed response. The models returned R² values of 0.73 for benzene, 0.78 for toluene and 0.74 for xylene, with adjusted R² values of 0.65, 0.72 and 0.68 respectively. Contact time was not a significant factor and solvent mass fraction was the dominant one. Individually optimised predicted efficiencies were 98.7% for benzene, 97.6% for toluene and 82.2% for xylene, obtained at closely similar conditions near 446 rpm, a solvent mass fraction of 0.20 and 55 °C. At independent test conditions within the design space, the model-to-experiment deviations were 2.1% for benzene and 10.0% for toluene, at or within the 10% acceptance criterion, while the xylene model deviated by 19.7% and is not considered validated for prediction. Benzene extraction stayed high in real refinery wastewater, above 95.8% by UV-Vis estimate. The observed extraction order, benzene > toluene > xylene, may reflect differences in the aqueous phase availability of the three analytes rather than hydrophobicity alone. Efficiencies are reported as aqueous phase depletion measured by UV-Vis, without HDES-free controls or chromatographic confirmation. Within these limits, the HDES shows promise for benzene removal from refinery effluent, although its environmental performance and its stability on reuse were not assessed in this study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hydrophobic deep eutectic solvents for carotenoid extraction from tomato pomace: Solvent screening and effect of extraction conditionsFood Chemistry · 2026
- Harnessing deep eutectic solvents for the extraction of biomolecules from plant waste: Their industrial applications, optimization, and mechanistic structureNext Sustainability · 2026
- Deep Eutectic Solvents for Sustainable Extraction of Bioactive Compounds from Biomass: Mechanistic Insights and Scale-Up ChallengesMolecules · 2026
- Hydrophobic (deep) eutectic solvents: from characterization and modeling to rational design and applications.RSC advances · 2026
- A simple and quick approach for the determination of phthalic acid esters in beverage samples using temperature-assisted hydrophobic deep eutectic solvent-based dispersive liquid-liquid microextraction.Journal of chromatography. A · 2026
- Deep eutectic solvents for green extraction of plant essential oils: mechanisms, critical review, and future perspectives.Critical reviews in food science and nutrition · 2026