Distinct hemodynamic implications of junctional rhythm versus sinus rhythm on cardiac reverse remodeling after the Maze procedure.
Hee Jeong Lee, YoHan Bae, Jung Uk Woo, Sungsil Yoon, Woo Sung Jang, Yun Seok Kim, Jonghoon Yoo, Kyungsub Song
Department of Cardiology, Keimyung University Dongsan Hospital, Keimyung University College of Medicine, Daegu, Republic of Korea. · Department of Thoracic and Cardiovascular Surgery, Keimyung University Dongsan Hospital, Keimyung University College of Medicine, Daegu, 42601, Republic of Korea.
Key points
From the paper's conclusion- JR is not a benign alternative to sinus rhythm; it mimics AF in preventing cardiac reverse remodeling and carries a high risk of pacemaker dependency. Therefore, JR should be clinically differentiated from NSR and recognized as a suboptimal hemodynamic outcome similar to AF.
Abstract
BACKGROUND: Surgical success after the Maze procedure is conventionally defined as "freedom from atrial fibrillation (AF)," often grouping junctional rhythm (JR) with normal sinus rhythm (NSR). However, the specific hemodynamic impact of JR remains poorly understood. This study investigated whether JR truly represents a successful outcome compared to NSR and AF. METHODS: We retrospectively analyzed patients undergoing the Maze procedure (2012-2024). After designating the first postoperative month as a blanking period for rhythm instability, we included only patients maintaining a consistent rhythm without crossover from 1 to 12 months postoperatively: AF (n = 71), NSR (n = 213), and JR (n = 35). Outcomes included cardiac reverse remodeling-assessed by left atrial contractile strain (LASct) and chamber dimensions-and permanent pacemaker (PPM) implantation. RESULTS: In the IPTW-adjusted cohort, the NSR group achieved significant cardiac reverse remodeling, characterized by improved LVEF (58.5%), reduced LA volume index (75.1 mL/m²), and notable recovery of LASct. In stark contrast, the JR group failed to show any reverse remodeling or mechanical recovery, exhibiting hemodynamic stagnation indistinguishable from the AF group. Consequently, no significant difference in cardiac function was observed between the JR and AF groups. Furthermore, the JR group faced a drastically elevated risk of PPM implantation compared to both the NSR and AF groups (P < 0.001). CONCLUSIONS: JR is not a benign alternative to sinus rhythm; it mimics AF in preventing cardiac reverse remodeling and carries a high risk of pacemaker dependency. Therefore, JR should be clinically differentiated from NSR and recognized as a suboptimal hemodynamic outcome similar to AF.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Risk of Atrial Fibrillation Recurrence After Modified Cox-Maze IV Surgery: Comparing Atrial Functional Mitral Regurgitation and Rheumatic Mitral Regurgitation.Reviews in cardiovascular medicine · 2026
- Biatrial Versus Left Atrial Maze Ablation During Cardiac Valve Surgery for Persistent Atrial Fibrillation: The ABLATION Trial.Circulation · 2026
- Impaired Left Atrial Contractile Strain and Late Pacemaker Implantation After the Cox-Maze Procedure Despite Maintained Sinus Rhythm.The Annals of thoracic surgery · 2026
- Junctional Rhythm Associated With Multilevel Flow Reversal in a Well-Functioning Fontan Detected by 4-Dimensional Flow.JACC. Case reports · 2026
- Concomitant surgical ablation for atrial fibrillation in mitral valve surgery: a systematic review of clinical outcomes and surgical strategies.Frontiers in cardiovascular medicine · 2026
- Clinical efficacy of minimally invasive cardiac valve surgery concomitant with radiofrequency ablation for atrial fibrillation: a single-center retrospective study.Journal of thoracic disease · 2026