Impaired Left Atrial Contractile Strain and Late Pacemaker Implantation After the Cox-Maze Procedure Despite Maintained Sinus Rhythm.
Jung Uk Woo, YoHan Bae, Hee Jeong Lee, Woo Sung Jang, Sungsil Yoon, Yun Seok Kim, Kyungsub Song
Medical Course, School of Medicine, Keimyung University College of Medicine, Daegu, Republic of Korea. · Department of Thoracic and Cardiovascular Surgery, Keimyung University Dongsan Hospital, Keimyung University College of Medicine, Daegu, Republic of Korea.
Key points
From the paper's conclusion- Impaired left atrial contractile strain 1 year after the Cox-Maze procedure independently predicts late pacemaker implantation despite stable normal sinus rhythm, particularly within the first 5 years, highlighting a dissociation between electrical and functional recovery. It may serve as a surrogate for atrial fibrosis and latent conduction disturbance, warranting intensified surveillance in high-risk patients during this period.
Abstract
BACKGROUND: Late bradyarrhythmia requiring permanent pacemaker implantation remains a challenge after the Cox-Maze procedure. We evaluated whether left atrial contractile strain at 1 year predicts late pacemaker implantation in patients with normal sinus rhythm. METHODS: We retrospectively analyzed 259 patients who underwent the Maze procedure between 2012 and 2024 and maintained normal sinus rhythm at 1 year. Left atrial contractile strain was assessed using two-dimensional speckle-tracking echocardiography. RESULTS: Of 329 patients screened, 50 were excluded for atrial fibrillation recurrence at 1 year (1-year freedom from atrial fibrillation, 83.8%). During follow-up (median 58 months), 22 patients required pacemaker implantation. The optimal strain cutoff was -1.8% (area under the curve 0.658), and patients with impaired left atrial function (strain ≥ -1.8%) had a higher incidence of pacemaker implantation (log-rank P < 0.001). Impaired left atrial contractile strain (hazard ratio 3.99; 95% confidence interval, 1.41-11.35), fine fibrillatory waves (3.64; 1.32-10.01), and increased preoperative left atrial volume (1.004 per mL; 1.001-1.008) were independent predictors, and a combined model improved predictive accuracy (area under the curve 0.782). The excess risk was concentrated within the first 5 years after surgery (hazard ratio 8.47 versus 2.22 thereafter). CONCLUSIONS: Impaired left atrial contractile strain 1 year after the Cox-Maze procedure independently predicts late pacemaker implantation despite stable normal sinus rhythm, particularly within the first 5 years, highlighting a dissociation between electrical and functional recovery. It may serve as a surrogate for atrial fibrosis and latent conduction disturbance, warranting intensified surveillance in high-risk patients during this period.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Left atrial contraction strain as a predictor of device-detected atrial fibrillation in patients with heart failure with reduced ejection fractionEuropean Heart Journal · 2026
- Left Atrial Strain Prediction of New-Onset Atrial Fibrillation in Apical Hypertrophic Cardiomyopathy with Cardiac MRI.Radiology. Cardiothoracic imaging · 2026
- Long-term Outcomes of the Cox-Maze Procedure in Patients With Atrial Septal Defect and Atrial Fibrillation.Korean circulation journal · 2026
- Prognostic value of left atrial stiffness index for incident heart failure in paroxysmal atrial fibrillation: a prospective cohort studyEuropean Heart Journal · 2026
- Predicting Atrial Fibrillation Risk in Hypertrophic Cardiomyopathy Patients: Left Atrial Phasic Function and Strain Mechanics.CJC open · 2026
- Prognostic associations of left atrial strain with major adverse cardiovascular events and atrial fibrillation: Data from the Akershus cardiac examination (ACE) 1950 study.International journal of cardiology · 2026