Repeatability and validity of a novel method for assessing patellar alignment using ultrasonography and three-dimensional motion capture: a pilot in vivo validation study
Yasuhiro Mitani, Hitoshi Koda, Atsushi Ueda, Toshimitsu Ohmine, Mizuki Nakamura, Maki Koyanagi
Key points
From the paper's conclusion- We developed a method that integrates ultrasonography with three-dimensional motion capture.
Abstract
Background Patellar tendinopathy is a prevalent overuse injury among athletes engaged in repetitive jumping activities and is associated with excessive and repetitive mechanical loading of the knee extensor mechanism. Patellar alignment influences patellar tendon loading. Conventional assessment methods rely on radiography or magnetic resonance imaging; however, these modalities have limitations, including radiation exposure and high cost. We developed a method that integrates ultrasonography with three-dimensional motion capture. Although validation in a bone model has been reported, in vivo validity remains unclear. This study examined the in vivo repeatability and validity of the proposed method. Methods Seven healthy males were enrolled. At knee flexion angles of 30°, 60°, and 90°, the patella–patellar tendon angle and the Insall–Salvati ratio were calculated using bony landmarks on ultrasonographic images combined with three-dimensional marker coordinates. Intrarater repeatability was assessed from three measurements per condition. The intraclass correlation coefficients, standard error of measurement, and minimal detectable change were calculated. Validity was assessed using magnetic resonance imaging-derived measurements as the reference standard. The mean absolute error, percent error, limits of agreement, and systematic error (fixed and proportional bias) were evaluated. Results Intraclass correlation coefficients exceeded 0.9 for the patella–patellar tendon angle and 0.8 for the Insall–Salvati ratio, indicating good to excellent within-session intrarater repeatability. The mean absolute error ranged from 1.6 to 3.0° for the patella–patellar tendon angle, with a percent error of less than 2%. For the Insall–Salvati ratio, the mean absolute error ranged from 0.04 to 0.10. A fixed bias was observed only at 30° for the Insall–Salvati ratio; however, no significant proportional bias was observed. Conclusions In this pilot study, the proposed method demonstrated good to excellent within-session intrarater repeatability and relatively small differences from MRI-derived measurements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of View-Specific Markerless Motion Analysis for Lower-Extremity Kinematics After Anterior Cruciate Ligament ReconstructionSensors · 2026
- External Adhesive Marker Technique Shows Excellent Reproducibility for Measuring Patellar Tendon-to-Lateral Trochlear Ridge Distance on Magnetic Resonance Imaging.Arthroscopy, sports medicine, and rehabilitation · 2026
- Comment on "Radiological risk factors in different patterns of patellar instability".Knee surgery & related research · 2026
- Inter-examiner and inter-day reliability of dynamic tibiofemoral movements measurement using motion capture during walking and jumping tasksThe Knee · 2026
- Reliability of Ultrasound Measurements in the Assessment of Femoral Trochlear Morphology in Healthy AdolescentsDiagnostics · 2026
- Knee Malposition During Radiographs Can Produce Clinically Relevant Errors in Measurements of Patellar Height.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026