Advanced HyperSight™ imaging for patients with adaptive SBRT of prostate cancer: a longitudinal analysis of tissue demarcation
Ralf Schmidt, Thanh Nguyen, Alicia S. Bicu, Paula Cvachovec, Victor Siefert, Miriam Eckl, Marvin Willam, Matthias F. Froelich,
Heidelberg University · University of Mannheim
Key points
From the paper's conclusion- High-quality imaging for adaptive SBRT in prostate cancer is provided by hCBCT, which offers equivalent tissue visualization compared to pCT.
Abstract
BACKGROUND: Cone-beam computed tomography (CBCT)-based adaptive radiotherapy (ART) at the Ethos® linear accelerator (eLinac) allows for daily anatomical and dosimetric adjustments and relies on robust image quality. This study evaluated the longitudinal image quality of the novel HyperSightTM-CBCT (hCBCT) compared to planning CT (pCT), using phantoms and data of prostate cancer patients undergoing adaptive stereotactic body radiotherapy (SBRT). Building on this, the longitudinal contour sharpness of the organs in fractional hCBCT and their usability for ART workflow across fractions was evaluated. METHODS: Between December 2023 and May 2024, 26 prostate cancer patients receiving ART at the eLinac with hCBCT technology were enrolled. Phantom studies assessed pCT and hCBCT image quality. Patient based analyses of all 156 imaging scans (pCT and each of the fractional hCBCT) analyzed, longitudinally examined firstly image quality, secondly contour sharpness of prostate, seminal vesicles, and rectal wall, and thirdly confidence to delineate the structures for the ART workflow. Time required for the ART based parameters were recorded. Quantitative metrics included CT number changes in the fat adjacent to the prostate and seminal vesicles. Friedman’s test with Bonferroni correction, Spearman and Intraclass Correlation Coefficient (ICC) were used for statistics. RESULTS: hCBCT scans showed robust image quality parameters in the phantom and patient based analysis across fractions. Inter-observer agreement was moderate, with lower rating score for resident compared to the experienced radiation oncologist (p < 0.001). Patient based analysis showed no significant differences of the contour sharpness of the prostate and seminal vesicles between pCT and initial hCBCT scan, but contour sharpness ratings declined across treatment fractions. Confidence for the delineation of prostate and seminal vesicles during ART was significantly decreased at later fractions (each padj<0.05) and this correlated significantly with longer assessment times (padj≤0.05). The CT attenuation of the fat tissue adjacent to the prostate and seminal vesicles significantly increased across the fractions (padj<0.05). CONCLUSIONS: High-quality imaging for adaptive SBRT in prostate cancer is provided by hCBCT, which offers equivalent tissue visualization compared to pCT. Fraction-dependent decreases in contour sharpness can be detected using longitudinal hCBCT imaging. These decreases are likely related to treatment-induced tissue changes and may impact ART workflow. The rating of the observed effects may potentially be influenced by the observer’s experience.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A clinical evaluation of HyperSight CBCT enhanced offline adaptive breast radiotherapy.Frontiers in oncology · 2026
- Automated offline adaptive radiotherapy through CBCT imaging: A multidimensional feasibility study of hypersight and iterative CBCTJournal of Applied Clinical Medical Physics · 2026
- Evaluating Image Quality of Cone Beam Computed Tomography Using HyperSight® on the Varian TrueBeam.Annals of biomedical engineering · 2026
- Task-based image quality and dosimetric validation of HyperSight CBCT for adaptive radiotherapy.Journal of applied clinical medical physics · 2026
- Feasibility of automated AI-based contouring and stable radiomic feature assessment by HyperSight-CBCT Imaging for adaptive high-precision radiotherapy of prostate cancerScientific Reports · 2026
- Image quality robustness of HyperSight‐enabled versus conventional iterative cone‐beam CT across patient size and imaging geometryJournal of Applied Clinical Medical Physics · 2026