Label-free dynamic cell imaging of fresh ex vivo spinal meningiomas: a nine-case optical-pathological correlation study with specimen-level H&E references.
Boyan Su, Panqi Yang, Yuzhe Ying, Li Li, Zhe Meng, Letao Tan, Kaiyu Zheng, Guihuai Wang,
Department of Neurosurgery, School of Clinical Medicine, Tsinghua Medicine, Beijing Tsinghua Changgung Hospital, Tsinghua University, Beijing, 102218, China. · Department of Physics, State Key Laboratory of Low-dimensional Quantum Physics, Tsinghua University, Beijing, China.
Key points
From the paper's conclusion- In nine fresh ex vivo spinal meningiomas, DCI showed regional correspondence with conventional H&E for cellular architecture, collagenous stroma, and psammomatous calcification, with specimen-level H&E available for every case. These descriptive, unblinded findings do not replace histopathology, and subtype and grade assignment remain dependent on permanent pathology. The findings support prospective workflow testing of DCI as a fresh-tissue survey method for representative sampling before permanent pathology, ancillary testing, molecular studies, and biobanking.
Abstract
BACKGROUND: Spinal meningioma subtype and grade still rest on haematoxylin and eosin (H&E) morphology, but permanent sections become available only after fixation and embedding, and intraoperative assessment of fresh tissue relies mainly on frozen section. Dynamic cell imaging (DCI), a label-free readout from dynamic full-field optical coherence tomography, images unprocessed specimens within minutes. Whether its regional signal corresponds to H&E in spinal meningioma has not been described. METHODS: We imaged nine fresh ex vivo spinal meningioma specimens by DCI on an active phase modulation-assisted dynamic full-field OCT (APMD-FFOCT) platform. All specimens were transported on ice and imaged at approximately 60 min after resection: eight CNS WHO grade 1 tumours (psammomatous, n = 3; transitional, n = 2; meningothelial, n = 1; not further subtyped, n = 2) and one meningioma, CNS WHO grade 3. Every specimen had a specimen-level H&E reference from the same fragment, without pixel-level co-registration. Six author-defined DCI features were recorded descriptively against conventional H&E, Ki-67, and available immunohistochemistry. Selected DCI-derived virtual H&E renderings were compared visually with conventional H&E but were not used as diagnostic references. Diagnostic accuracy, blinded subtype assignment, reader agreement, and ROC analysis were not assessed. RESULTS: In all three psammomatous cases, DCI showed round or concentric signal-poor foci within whorl-like regions; specimen-level H&E showed corresponding psammoma bodies and meningothelial whorls. Both transitional cases showed mixed fascicular and whorl-like patterns; meningothelial case and the two grade 1 cases without a specific histological subtype showed sheet-like, lobular, or mixed patterns. Dark fibrillar DCI signal was compatible with collagenous stroma. The grade 3 case showed disorganised hypercellular texture without whorls and a Ki-67 index of 70%; Ki-67 was 3-10% in grade 1 tumours. Virtual H&E renderings displayed selected DCI fields in an H&E-like colour space and were treated only as visual aids. CONCLUSIONS: In nine fresh ex vivo spinal meningiomas, DCI showed regional correspondence with conventional H&E for cellular architecture, collagenous stroma, and psammomatous calcification, with specimen-level H&E available for every case. These descriptive, unblinded findings do not replace histopathology, and subtype and grade assignment remain dependent on permanent pathology. The findings support prospective workflow testing of DCI as a fresh-tissue survey method for representative sampling before permanent pathology, ancillary testing, molecular studies, and biobanking.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP03.19 Procedural comparison between classical and digital intraoperative rapid section diagnosis with multiphoton microscopy in neurosurgeryNeuro-Oncology · 2026
- Double Staining Immunohistochemistry and Digital Pathology: Moving Towards Standardization of the Proliferative Index Evaluation in MeningiomasJournal of Personalized Medicine · 2026
- P07.01.A Near-real-time virtual histology for intraoperative neuro-oncology using multiphoton microscopy in 100 neurosurgical specimensNeuro-Oncology · 2026
- Review of dynamic optical coherence tomography for intracellular motility: signals, metrics, and their applications [Invited]Biomedical Optics Express · 2025
- Feasibility of Real-Time Cellular Imaging Using a Miniaturized Epifluorescence Widefield Microscope for Intraoperative Margin Assessment in Intracranial Tumor Resection: A Pilot Study.World neurosurgery · 2026
- Diffusion MRI radiomics in meningiomas: imaging correlates of tumor grade and intraoperative consistency.Neurosurgical focus · 2026