Spatial accuracy and clinical feasibility of CT/US fusion imaging for hepatic interventions in dogs.
Hye-Won Lee, Kija Lee, Sang-Kwon Lee
Department of Veterinary Medical Imaging, College of Veterinary Medicine, Kyungpook National University, Daegu, 41566, Republic of Korea. · Department of Veterinary Medical Imaging, College of Veterinary Medicine, Kyungpook National University, Daegu, 41566, Republic of Korea. sklee10@knu.ac.kr.
Key points
From the paper's conclusion- CT/US fusion imaging provided rapid, accurate, and visually reliable co-registration of canine liver anatomy, supporting its potential clinical use for image-guided hepatic interventions in dogs.
Abstract
BACKGROUND: Computed tomography (CT)-ultrasound (US) fusion imaging is widely used for hepatic interventions in human medicine, but its technical performance has not been evaluated in dogs. This study assessed the spatial accuracy, fusion time, and image quality of CT/US fusion imaging in the canine liver. METHODS: In this prospective experimental study, ten healthy Beagle dogs underwent contrast-enhanced abdominal CT followed immediately by CT/US fusion imaging under the same general anesthesia without repositioning. Fusion was performed at three scan sites (midline subcostal, right intercostal, and left intercostal) using plane registration and three-point manual landmark registration with the gallbladder (GB) as the target structure. Spatial accuracy was quantified as the positional discrepancy between the CT and US GB margins in transverse (left-right, ventral-dorsal) and sagittal (cranial-caudal) planes. Fusion quality was scored on a 5-point scale for the GB center, GB border, vessel alignment, and liver surface alignment. Statistical analyses were performed using nonparametric tests with a significance threshold. RESULTS: Fusion was successful in 58/60 planned image sets; two subcostal studies failed due to intragastric gas. The mean fusion time was 72.7 ± 30.2 s and did not differ significantly among scan sites. Across all sites and planes, the mean CT/US discrepancies were ≤ 2 mm. Qualitative scores were uniformly high (median 5 for all criteria) without relevant site- and plane-dependent degradation. CONCLUSIONS: CT/US fusion imaging provided rapid, accurate, and visually reliable co-registration of canine liver anatomy, supporting its potential clinical use for image-guided hepatic interventions in dogs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Assessment of the accuracy and feasibility of CT fusion with real-time US guidance for percutaneous radiofrequency trigeminal rhizotomy.European journal of radiology · 2026
- Three-dimensional ultrasonographic assessment of the cranial cruciate ligament in medium- to large-sized canine cadavers: a feasibility study.Veterinary journal (London, England : 1997) · 2026
- An ultra-low indocyanine green dose maximizes biliary-to-hepatic contrast in dogs: a prospective pilot study.Veterinary journal (London, England : 1997) · 2026
- Educational utility of a 3D-printed canine hepatic artery phantom for CT bolus tracking training.Alternatives to laboratory animals : ATLA · 2026
- Real-time CT/MR fusion imaging-guided core needle biopsy: enhancing diagnostic precision in head and neck lesions.Insights into imaging · 2026
- Computed tomography extracellular volume fraction in canine hepatic fibrosis: a retrospective preliminary study.Veterinary journal (London, England : 1997) · 2026