Primary stability of short implants compared with standard implants placed with a simulated closed sinus floor elevation technique: an in vitro study
Emrah Genceli, Hilal Ağar, Süleyman Çağatay Dayan, Serdar Çintan, Emine Çifcibaşı
Key points
From the paper's conclusion- Short implants and standard implants placed following simulated closed sinus floor elevation were evaluated using resonance frequency analysis and Periotest measurements ( n = 40).
Abstract
Background Primary implant stability is a key determinant of successful osseointegration, particularly in the posterior maxilla, where bone quality is often compromised. Short implants have been proposed as an alternative to sinus floor elevation; however, data comparing their primary stability with that of standard implants placed using closed sinus floor elevation remain limited. This in vitro study aimed to compare the primary stability of short and standard implants. Materials and methods An in vitro experimental model was used to assess primary implant stability. Short implants and standard implants placed following simulated closed sinus floor elevation were evaluated using resonance frequency analysis and Periotest measurements ( n = 40). Implant stability values were obtained from frontal and lateral directions, with five readings averaged in each direction for every implant. Descriptive statistics were calculated, and group comparisons were performed. Pearson correlation analysis was used to evaluate relationships between measurement directions within each implant group and between assessment methods. Results No statistically significant differences in primary stability were observed between short implants and standard implants based on either resonance frequency analysis or Periotest measurements ( p > 0.05). Conclusions Within the limitations of this in vitro model, no statistically significant difference in primary stability was detected between short and standard implants under similar crestal bone engagement. As healing, secondary stability, and loading were not assessed, clinical studies are required to confirm these findings. Trial registration Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Primary Stability of an Expandable Versus a Conventional Short Implant in Low-Density Bone: A Density-Stratified Ex Vivo Comparison.Dentistry journal · 2026
- Short Implants Versus Sinus Floor Elevation With Standard Implants in the Atrophic Posterior Maxilla: A Systematic Review and Meta-Analysis.Cureus · 2026
- Effect of Progressive Versus Standard Implant Thread Designs on Primary Stability and Insertion Torque: An In Vitro StudyThe International Journal of Oral & Maxillofacial Implants · 2026
- Primary Stability of Implants Inserted Using Different Osseodensification Systems in Low-Density Bone: An In Vitro StudyDentistry Journal · 2026
- The Early Stability of Short vs. Standard Dental Implants with Identical Shallow-Thread in the Posterior Region of the Mandible: A Prospective Pilot Study.The International journal of oral & maxillofacial implants · 2026
- Influence of Implant Macrogeometry on Primary Stability in Different Polyurethane Bone-Density Models: An In Vitro Study.Bioengineering (Basel, Switzerland) · 2026