Clinical accuracy of transferring virtually planned zygomatic implant positions in severely atrophic maxilla: a single-arm study.
Mahmoud Mohamed Hassan Agha, Ahmed Abdelmohsen Younis Ahmed Ali, Mohamed Ahmed ElSholkamy, Amr Aly El Swify
Faculty of Dentistry, Suez Canal University, Ismailia, Egypt. mahmoud_moh.agha@dent.suez.edu.eg. · Oral and Maxillofacial Surgery Department, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt.
Key points
From the paper's conclusion- These findings describe short-term positional accuracy and should not be interpreted as evidence of long-term implant stability, treatment efficacy, or overall safety.
Abstract
OBJECTIVES: This study aimed to evaluate the clinical accuracy of transferring virtually planned zygomatic implant positions in severely atrophic maxilla. MATERIALS AND METHODS: This clinical accuracy study included 24 participants with severely atrophic edentulous maxilla. All cases were digitally planned using cone-beam computed tomography (CBCT) and treated with bilateral zygomatic implants under general anesthesia, with additional anterior conventional implants. Postoperative CBCT was used to superimpose the actual implant positions onto the virtual plan and assess coronal and apical deviations. RESULTS: A total of 48 zygomatic implants were placed in 24 participants. Three-dimensional superimposition of the preoperative virtual plans and postoperative CBCT scans demonstrated a mean coronal deviation of 1.917 ± 0.401 mm overall, with values of 1.989 ± 0.540 mm on the right side and 1.846 ± 0.160 mm on the left side. The overall mean apical deviation was 1.733 ± 0.429 mm, with values of 1.757 ± 0.172 mm on the right side and 1.709 ± 0.588 mm on the left side. CONCLUSIONS: Virtual surgical planning enabled the transfer of planned zygomatic implant positions with measurable coronal and apical deviations. These findings describe short-term positional accuracy and should not be interpreted as evidence of long-term implant stability, treatment efficacy, or overall safety. TRIAL REGISTRATION: Trial was retrospectively registered on 31/03/2023 at Pan African Clinical Trials Registry ( https://pactr.samrc.ac.za ) (ID: PACTR202603707948061) under the following link: https://pactr.samrc.ac.za/TrialDisplay.aspx?TrialID=40945 .
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Digital Planning for Navigation-assisted Zygomatic Implant Rehabilitation: A Case Report.The International journal of prosthodontics · 2026
- Accuracy of Zygomatic Implant Placement Using Completely Versus Partially GuidedBMC Oral Health · 2026
- Evaluation of Trabecular Bone Microarchitecture for Zygomatic Implants: A Cone Beam Computed Tomography Study.Diagnostics (Basel, Switzerland) · 2026
- Accuracy of guided midface surgery in complex craniomaxillofacial anomalies.International journal of oral and maxillofacial surgery · 2026
- Accuracy of Dynamic Computer-Assisted Surgery for Pterygoid Implant Placement in Fully and Partially Edentulous Maxillae: A Retrospective Comparative Study.Medicina (Kaunas, Lithuania) · 2026
- The influence of preoperative planning on the accuracy of dynamic navigation-assisted zygomatic implant placement: a retrospective study.International journal of oral and maxillofacial surgery · 2026