Comparative assessment of CBCT and digital radiography in quantifying periapical pathology (in vitro study).
Abdelmonem Dahrous, Hassan Mohamed Abouelkheir, Esraa A Elnadoury
Bachelor of Dentistry, FacultyofDentistry, Alexandria University, Alexandria, Egypt. · Department of Oral Medicine, Oral Periodontology, Oral Diagnosis and Oral Radiology, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Key points
From the paper's conclusion- While CBCT is more reliable than PR, its precision is influenced by lesion size, performing most accurately with larger periapical pathologies.
Abstract
OBJECTIVE: To compare the diagnostic accuracy of phosphor plate-based digital periapical radiography (DPR) and CBCT in quantifying periapical lesions compared to the reference standard. MATERIALS AND METHODS: This in vitro study included 45 premolar teeth with simulated periapical lesions created in dry human mandibles. The lesions were categorized into three groups according to size. All specimens were imaged using DPR with the paralleling technique (70-80kVp, 8mA, 0.16-0.32s). CBCT imaging was performed using the i-CAT Next Generation system (120kVp, 5mA, 26.9s, 0.25mm voxel size). Lesion lengths obtained from both imaging modalities were compared with the actual lesion dimensions (reference standard) to assess diagnostic accuracy. Intra-examiner reliability was evaluated. RESULTS: Group I's mean lesion length was 1.2mm, Group II's was 1.5mm, and Group III's was 1.8mm. In comparison to the reference standard, PR frequently overestimated the length of lesions. CBCT, on the other hand, showed better accuracy, and greater consistency. A propensity to underestimate minor lesions was indicated by the mean CBCT measurement of 1.07 ± 0.20mm at 1.2 mm group (p = 0.020). At 1.5mm, CBCT assessed 1.72 ± 0.19mm (p = 0.001) while no significant difference observed at 1.8mm (p = 0.065). CONCLUSIONS: While CBCT is more reliable than PR, its precision is influenced by lesion size, performing most accurately with larger periapical pathologies. CLINICAL RELEVANCE: Periapical radiography should be interpreted with caution when assessing periapical pathology, as it may lead to overestimation of lesion size. In contrast, CBCT can be regarded as the reference standard, especially for lesions larger than 1.5mm.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Diagnostic performance of clinical photon-counting CT in the assessment of peri-implantitis - an ex vivo diagnostic accuracy study.International journal of implant dentistry · 2026
- Diagnostic accuracy of artificial intelligence in detecting periapical lesions: A comparative study with cone-beam computed tomography and conventional periapical radiography.Journal of clinical and experimental dentistry · 2026
- Diagnostic accuracy of cone beam computed tomography in the detection of furcation perforations: an in vitro comparison with periapical radiography and micro-computed tomography.BMC oral health · 2026
- Diagnostic accuracy of CBCT versus digital radiography for early detection of peri-implant bone loss: a retrospective study with threshold and observer variability analysis.Frontiers in dental medicine · 2026
- Reference Standards in Artificial Intelligence Detection of Apical Periodontitis: A Narrative Review of What Reported Accuracy Measures.Diagnostics (Basel, Switzerland) · 2026
- Accuracy of panoramic radiography, periapical radiography, and CBCT in diagnosing apical root resorption.Brazilian oral research · 2026