The effect of radiotherapy and surface treatment on immediate repair bond strength of two CAD/CAM materials.
Zeinab Mohammed Morsy, Reham Mohamed Mohamed Salem, Somaia Metwally ElSayed, Ahmed Adel Abdelaziz, Amin Elsayed Amin, Farid El-Askary
Operative Dentistry Department, Faculty of Dentistry, Benha National University, Al Qalubiya, Egypt. zeinabmorsy177@gmail.com. · Operative Dentistry Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
Key points
From the paper's conclusion- No significant difference in bond strength between surface treatments was found for the lithium disilicate material ( p = 0.423), whereas the Resin composite showed a significant difference ( p = 0.03).
Abstract
BACKGROUND: Patients undergoing radiotherapy often have limited tolerance for extensive restorative procedures. Therefore, repair of defective restorations using minimally invasive approaches is preferred. This study investigated the effects of radiotherapy and surface treatment on the repair micro-shear bond strength (µSBS) and nanoleakage (NL) of two water-stored CAD/CAM materials. METHODS: Eighty CAD/CAM specimens were stored in water for 6 months and assigned to eight groups according to irradiation exposure (irradiated or non-irradiated), material type [lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar-Vivadent, Liechtenstein) or CAD/CAM composite blocks (Grandio Blocs, VOCO, Germany), and surface treatment (abrasive bur or abrasive bur + silicon carbide (SiC) conditioning bur). For each material, irradiated specimens (single 6 meV irradiation dose) and non-irradiated specimens were initially prepared using an abrasive bur. Half of the specimens were subsequently conditioned using a SiC bur, while the remaining half received no additional SiC bur conditioning. Three composite cylinders were bonded to each specimen and subjected to µSBS testing at a crosshead speed of 0.5 mm/min. Fracture modes was evaluated using stereomicroscopy and NL was qualitatively assessed for the presence or absence of silver nitrate deposits using SEM. Data were analyzed using ANOVA followed by Tukey's post hoc test (α = 0.05). RESULTS: µSBS was significantly influenced by irradiation (p < 0.0001), material type (p < 0.0001), and surface treatment (p = 0.039). The highest µSBS value (29.50 ± 3.13 MPa) was observed in non-irradiated CAD/CAM Resin Composite specimens treated with AB and SiC, whereas the lowest value (8.78 ± 1.72 MPa) was recorded in irradiated lithium disilicate specimens treated with AB alone. No significant difference in bond strength between surface treatments was found for the lithium disilicate material (p = 0.423), whereas the Resin composite showed a significant difference (p = 0.03). Adhesive failure predominated in lithium disilicate specimens (72.3%), while mixed failure predominated in CAD/CAM composite specimens (50%). No silver nitrate deposition was detected with respect to material type, irradiation, or surface treatment. CONCLUSION: For irradiated patients, SiC conditioning bur seemed to be considered as extra step that does not enhance the repair SBS of CAD/CAM materials evaluated in this study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Evaluation of the Effect of Radiation on the Marginal Adaptation of Different Composite Restorative Materials: An In Vitro Study.Cureus · 2026
- The Effect of Radiotherapy on the Microtensile Bond Strength of Dentin in Relation to the Timing of Restoration Procedure.International journal of dentistry · 2026
- Effect of fractionated therapeutic radiotherapy on surface microhardness and roughness of giomer- and ormocer-based restorative composites: an in vitro studyScientific Reports · 2026
- Effect of photon radiotherapy on microleakage and microhardness of nanohybrid resin composite restoration: an in vitro study.BMC oral health · 2026
- Repair Bond Durability of Selected Thermally Aged CAD/CAM-Milled and 3D-Printed Provisional Restorative Materials Following Different Surface Treatment Protocols: A Comparative In Vitro StudyJournal of Functional Biomaterials · 2026
- Study on the influence of fixed dental prostheses on radiotherapy dose distribution based on dual-layer detector spectral CT imaging.Frontiers in oncology · 2026