BMC oral health

Microbial sealing and physicochemical degradation of composite resin seals in implant screw access channels: an in vitro study.

Yong-Qing Guo, Zi-En Wang, Hao Yu

Clinical Research Center for Oral Tissue Deficiency Diseases of Fujian Province & Fujian Key Laboratory of Oral Disease & Fujian Provincial Engineering Research Center of Oral Biomaterial, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350002, China. · Clinical Research Center for Oral Tissue Deficiency Diseases of Fujian Province & Fujian Key Laboratory of Oral Disease & Fujian Provincial Engineering Research Center of Oral Biomaterial, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350002, China. haoyu-cn@hotmail.com.

Preclinical · n=16

Key points

From the paper's conclusion
  • The interfacial sealing of SACs is predominantly governed by the bulk physicochemical properties of the restorative material and its composite thickness, rather than the adhesive protocol. A 3 mm thickness of high-viscosity universal composite is suggested to improve resistance against microbial leakage.

Abstract

BACKGROUND: The screw access channel (SAC) is a known vulnerability in screw-retained implant restorations. Despite its clinical importance, there is no established consensus on the optimal protocol for achieving a predictable seal. This study aimed to investigate the effects of restorative material category (high-viscosity, packable, and flowable), composite thickness, and adhesive strategy on microbial leakage, bond strength, and physicochemical stability within simulated zirconia SACs. METHODS: A total of 192 zirconia specimens with standardized SACs were randomly assigned to 12 experimental protocols (n = 16). The experimental variables included three composite resins with distinct handling characteristics (High-viscosity universal: Magnafill Putty [MP]; Packable: Filtek Bulk Fill [BF]; Flowable: Filtek Supreme XTE Flowable [XTF]), two restorative thicknesses (2 mm and 3 mm), and two bonding agents (Scotchbond Universal and G-Bond). Sealing performance was quantified via Streptococcus mutans microleakage and push-out bond strength (POBS) across independent non-aged and thermocycled subgroups (10,000 thermocycles, 5-55 °C, n = 8/subgroup). Hydrolytic stability was evaluated through water sorption and solubility. Data were analyzed using three-way ANOVA and Tukey post-hoc tests (α = 0.05). RESULTS: Microbial leakage was significantly influenced by the composite category and restorative thickness (P < 0.05), whereas the choice of bonding agent exerted a negligible influence (P > 0.05). The high-viscosity universal resin (MP) applied at a 3 mm thickness exhibited the lowest microbial infiltration (P < 0.05). Furthermore, water sorption and solubility were primarily material-dependent, with the high-viscosity resin demonstrating superior resistance to hydrolytic degradation. Thermocycling significantly compromised the POBS across all groups (decreasing from a range of 7.64-10.65 MPa to 3.27-4.96 MPa, P < 0.05). CONCLUSIONS: The interfacial sealing of SACs is predominantly governed by the bulk physicochemical properties of the restorative material and its composite thickness, rather than the adhesive protocol. A 3 mm thickness of high-viscosity universal composite is suggested to improve resistance against microbial leakage.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Microbial sealing and physicochemical degradation of composite resin seals in implant screw access channels: an in vitro study — Science Skim