Accuracy of PSI-based hybrid workflow using a temporary intermediate splint versus conventional splint-based maxillary positioning in orthognathic surgery: a retrospective cohort study.

Jonathan Bertram, Henry Leonhardt, Fred Podmelle, Thomas Teltzrow, Adrian Franke

Department of Oral and Maxillofacial Surgery, Facial Plastic Surgery, Ernst-Von-Bergmann Klinikum Potsdam, Charlottenstraße 72, Potsdam, 14467, Germany. · Department of Oral and Maxillofacial Surgery, Medical Faculty and University Hospital Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, Dresden, 01307, Germany.

Observational · n=15

Key points

From the paper's conclusion
  • The PSI-based hybrid workflow resulted in statistically greater positioning accuracy compared to conventional splint-based fixation. However, the absolute improvements (approximately 0.3 mm and 0.5°) were small, likely of limited clinical relevance, and were not associated with reduced operating times. Due to the retrospective, non-randomised design, small sample size, and use of a PSI-based hybrid protocol, these findings should be considered hypothesis-generating. Larger prospective studies evaluating fully splintless PSI workflows and patient-centred outcomes are recommended.

Abstract

BACKGROUND: This retrospective cohort study, adhering to STROBE guidelines, compared the accuracy of maxillary positioning achieved with a patient-specific implant (PSI)-based hybrid workflow, which utilised a temporary intermediate splint to identify and remove posterior bony interferences before definitive splintless PSI fixation, to conventional splint-based positioning using stock titanium osteosynthesis plates in orthognathic surgery. Translational and rotational movement deviations from the virtual surgical plan were assessed. METHODS: Twenty-six patients who underwent non-segmental Le Fort I osteotomy between January 2020 and June 2023 were included. Eleven patients received the PSI-based hybrid workflow, while 15 patients underwent conventional splint-based positioning. Group allocation was based on the logistical feasibility of PSI planning and manufacturing rather than randomisation. Pre- and postoperative 3D images were superimposed using IPS® Case Designer software (KLS Martin) to quantify deviations in three translational and three rotational axes. Between-group comparisons were conducted using unpaired t-tests and two-way ANOVA, and correlations were assessed using Pearson's coefficient. RESULTS: The mean translational deviation was significantly lower in the PSI group compared to the control group (0.46 ± 0.33 mm vs 0.79 ± 0.58 mm; p = .0044), as was the mean rotational deviation (0.82° ± 0.91° vs 1.24° ± 0.85°; p = .0397). Significant differences were identified for vertical translation (p = .0162) and yaw rotation (p = .0205). Operating time did not differ significantly between groups (p = . 1739). In the PSI group, greater planned displacement showed a weak correlation with larger deviations, a relationship not observed in the control group. CONCLUSIONS: The PSI-based hybrid workflow resulted in statistically greater positioning accuracy compared to conventional splint-based fixation. However, the absolute improvements (approximately 0.3 mm and 0.5°) were small, likely of limited clinical relevance, and were not associated with reduced operating times. Due to the retrospective, non-randomised design, small sample size, and use of a PSI-based hybrid protocol, these findings should be considered hypothesis-generating. Larger prospective studies evaluating fully splintless PSI workflows and patient-centred outcomes are recommended. CLINICAL TRIAL NUMBER: Not applicable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers