Accuracy of Combined Osteotomy Guides and Patient-Specific Implants in Le Fort I Segmental Osteotomy Requiring Alveolar Bone Reduction.
Xinyu Xu, Ling Wu, Zili Li, Xiaojing Liu
Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology & National Center of Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, No. 22, Zhongguancun South Avenue, Haidian District, Beijing 100081, China.
Key points
From the paper's conclusion- Conclusions: The combined use of osteotomy guides and PSIs facilitates accurate 3D maxillary repositioning in segmental Le Fort I osteotomy involving alveolar bone reduction.
Abstract
Background: Segmental Le Fort I osteotomy combined with interdental alveolar bone reduction is a technically challenging procedure, and the accuracy of patient-specific implants (PSIs) in this setting has not been well established. This study aimed to assess the three-dimensional (3D) repositioning accuracy and safety of 3D-printed osteotomy guides used in conjunction with PSIs for this complex surgical procedure. Materials and Methods: This retrospective consecutive case series included 19 patients who underwent segmental Le Fort I osteotomy with alveolar bone reduction in the premolar region. For all patients, 3D-printed osteotomy guides and PSIs were designed using virtual surgical planning (VSP). Postoperative CBCT reconstruction models were superimposed on the VSP models to assess accuracy based on 3D deviations of skeletal and dental landmarks, angular discrepancies, and dental arch morphology. Residual intersegmental alveolar gaps and perioperative complications were also evaluated. Results: Signed and absolute coordinate deviations of all landmarks were within the 2 mm reference margin. Signed coordinate deviations differed significantly among the X-, Y-, and Z-axes (p < 0.05), with the X-axis showing the smallest mean deviation (0.064 ± 0.753 mm). The overall Euclidean spatial error was 1.477 ± 0.519 mm. Anterior maxillary segments exhibited significantly greater sagittal and vertical deviations than posterior segments (p < 0.05). The overall mean residual intersegmental alveolar gap was 0.681 ± 0.153 mm, with the buccal gap at the root apex significantly larger than the corresponding palatal gap (p < 0.05). Two minor dentin injuries occurred, neither of which resulted in clinical pulpal or periodontal complications during the available follow-up. Conclusions: The combined use of osteotomy guides and PSIs facilitates accurate 3D maxillary repositioning in segmental Le Fort I osteotomy involving alveolar bone reduction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of maxillary positioning in semi-guided orthognathic surgery using 3D-printed cutting guides and bending plates: A retrospective study.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Patient-Specific Versus Conventional Manually Bent Osteosynthesis Plates in Orthognathic Surgery: A Systematic Review and Meta-Analysis of Three-Dimensional Accuracy, Long-Term Skeletal Stability, Operative Efficiency, and Postoperative ComplicationsSurgeries · 2026
- Patient-specific implants and virtual surgical planning in surgery-first orthognathic surgery: a case series and review of literature.Journal of surgical case reports · 2026
- Translational and rotational accuracy of the mandibular proximal segment after virtual surgical planning-guided bilateral sagittal split ramus osteotomy in skeletal Class III patients.Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2026
- Two-Piece Multisegmental Le Fort I Osteotomy With 2 CAD/CAM Splints and a Real-Time Navigation System.The Journal of craniofacial surgery · 2026
- Ipsilateral tooth-registered surgical guides for minimally invasive Le Fort I osteotomy.International journal of oral and maxillofacial surgery · 2026