Comparative evaluation of canal transportation of DenFlex and ProTaper Gold rotary instruments in simulated S-shaped root canals: an in vitro study.
Mohammad Ashiani, Sara Navabi, Amirmohammad Moradpour, Maryam Forghani
Student Research Committee, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran. · Department of Endodontics, Mashhad University of Medical Sciences, Mashhad, Iran.
Key points
From the paper's conclusion- Both systems were able to prepare simulated S-shaped canals, but DenFlex induced greater canal transportation compared to ProTaper Gold.
Abstract
OBJECTIVE: Maintaining canal centering during preparation of severely curved root canals is still a major concern in endodontics. This study aimed to compare canal transportation in simulated S-shaped resin blocks instrumented with DenFlex (DenFlex, Seoul, South Korea) and ProTaper Gold (Dentsply Maillefer, Ballaigues, Switzerland) rotary file systems. METHODS AND MATERIALS: Thirty S-shaped resin blocks (16 mm length) were randomly assigned to two groups: DenFlex (prepared up to size 25/0.06) and ProTaper Gold (prepared up to F2). Before and after preparation, canals were filled with fuchsin red and methylene blue dyes, respectively. Canal transportation at the coronal, middle, and apical thirds was measured via superimposition of pre- and post-preparation images, which were captured under a stereomicroscope at ×40 magnification. Data were analyzed by repeated-measures ANOVA and independent t-tests (α = 0.05). RESULTS: A significant interaction was found between the file system and canal region (p < 0.001). DenFlex caused significantly greater transportation than ProTaper Gold at all regions (p < 0.001). For both systems, the highest transportation occurred in the middle third and the lowest in the apical third (p < 0.001). Four DenFlex files fractured during the procedure. CONCLUSION: Both systems were able to prepare simulated S-shaped canals, but DenFlex induced greater canal transportation compared to ProTaper Gold.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Comparative Evaluation of the Cyclic Fatigue Resistance of Three Nickel-Titanium Rotary File Systems in a Simulated Curved Canal: An In Vitro Study.Cureus · 2026
- Comparative evaluation of shaping ability of EdgeOne-R Utopia, One Reci, and WaveOne Gold in severely curved simulated root canals: an in vitro study.BMC oral health · 2026
- Cyclic Fatigue Resistance and Fractured Fragment Length of Three NiTi Rotary Systems: An In Vitro ComparisonOral · 2026
- Micro-CT Evaluation of Shaping Ability, Canal Transportation, and Centering Ability of Continuous Rotary and Reciprocating Systems in Maxillary Premolars.Medical science monitor : international medical journal of experimental and clinical research · 2026
- Shaping Performance of XP4 versus ProTaper Next in C-Shaped Canals: A Micro-CT Study of 3D-Printed Mandibular Second Molar Replicas.Clinical and experimental dental research · 2026
- Comparison of root canal geometry, performance and safety after preparation of a single root canal with contemporary instruments.Clinical oral investigations · 2026