Digital workflow for implant-supported restorations in the mandible including reverse scan bodies: a feasibility study.
Aiste Kernen-Gintaute, M Akulauskas, F Kernen, S Wenger, N U Zitzmann, B C Spies, F Burkhardt
Department of Prosthetic Dentistry, Center for Dental Medicine, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Hugstetter Str. 55, Freiburg, 79106, Germany. aiste.kernen@uniklinik-freiburg.de. · Biomedical Engineering Institute, Kaunas University of Technology, Kaunas, Lithuania.
Key points
From the paper's conclusion- Within the limitations of this single-patient evaluation and the favorable two-implant mandibular configuration, intraoral scanning provided sufficient accuracy for fabricating passively fitting restorations on two implants in the edentulous mandible. Measurable linear and angular deviations did not compromise clinical fit in this case. The use of reverse scan bodies may be effective in cases of misfit after intraoral re-splinting, especially in more complex full-arch workflows, as only minor linear and angular deviations were observed in the NVBs with integrated abutments.
Abstract
BACKGROUND: Completely edentulous mandibles present a challenge for accurate intraoral scanning, which can compromise the passive fit of implant-supported restorations. Reverse scan bodies may improve the accuracy of implant position transfer and support a fully digital workflow. However, clinical evidence for their use in the edentulous mandible remains limited. METHODS: In this single-patient prospective clinical evaluation, one fully edentulous mandible restored with two interforaminal implants was scanned ten times using an intraoral scanner (IOS). Based on each scan, titanium verification bars (VBs) were fabricated, and their passive fit was assessed clinically. After sectioning and intraoral re-splinting, splinted verification bars (SVBs) were digitized using reverse scan bodies and a laboratory scanner to fabricate new verification bars (NVBs). Linear and angular deviations between datasets (IOS, VB, SVB, NVB) were analyzed using metrology software and statistically evaluated with Welch's ANOVA and post hoc tests (α = 0.05). RESULTS: All VBs and NVBs demonstrated passive fit clinically. Mean linear deviations were 12 μm between IOS and VB, 50 μm between VB and SVB (p = 0.001), and 26 μm between SVB and NVB (p = 0.20). Mean angular deviations were 0.18° between IOS and VB, with six measurements > 0.4°; 0.79° between VB and SVB (p = 0.01), with seven measurements > 0.4°; and 0.06° between SVB and NVB, with four measurements > 0.4°. CONCLUSIONS: Within the limitations of this single-patient evaluation and the favorable two-implant mandibular configuration, intraoral scanning provided sufficient accuracy for fabricating passively fitting restorations on two implants in the edentulous mandible. Measurable linear and angular deviations did not compromise clinical fit in this case. The use of reverse scan bodies may be effective in cases of misfit after intraoral re-splinting, especially in more complex full-arch workflows, as only minor linear and angular deviations were observed in the NVBs with integrated abutments.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Model-free digital-correction workflow for multi-implant restorations: A clinical proof-of-concept study.Journal of prosthodontic research · 2026
- Influence of an indexing component and intraoral scanner type on the accuracy of reverse scan body digital implant scans.The Journal of prosthetic dentistry · 2026
- The accuracy of reverse scan body technique for capturing full-arch digital implant impressions: An in vitro study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Implant Position Accuracy of a Dual-Function Bite Holder for Single-Visit Registration of Complete-Arch Implants and Maxillomandibular Relationship: An In Vitro Study.The International journal of oral & maxillofacial implants · 2026
- Accuracy of Direct Intraoral Versus Reverse Scanning for Abutment-Level Implant Impressions: an In Vitro Study.European journal of dentistry · 2026
- Accuracy of digital impressions captured by an intraoral scanner in a partially edentulous mandible.Journal of dental sciences · 2026