Does operator experience affect root canal shaping quality with single-file NiTi Systems?
Vasfiye Isik, Mehmet Baybora Kayahan, Ibrahim H AbuTahun, Sang Won Kwak, Hyeon-Cheol Kim
Department of Endodontics, Division of Clinical Sciences, Faculty of Dentistry, Istanbul University- Cerrahpaşa, Kocamustafapaşa Cad No:53, Cerrahpaşa Campus, Fatih, Istanbul, 34098, Turkey. vasfiye86@hotmail.com. · Department of Endodontics, Division of Clinical Sciences, Faculty of Dentistry, Istanbul University- Cerrahpaşa, Kocamustafapaşa Cad No:53, Cerrahpaşa Campus, Fatih, Istanbul, 34098, Turkey. bayborakayahan@yahoo.com.
Key points
From the paper's conclusion- The results were analyzed using two-way analysis of variance, with operator experience and file system as fixed factors, followed by Tukey’s post hoc comparison at a significance level of 95%.
Abstract
BACKGROUND: This study aimed to evaluate the influence of the operator's experience on shaping ability with single-file Nickel-Titanium systems. METHODS: The One Curve (OC) rotary file system and the One RECI (OR) reciprocating file system, both with a tip size of #25/0.06, were used by four inexperienced clinicians (IOC and IOR) and four endodontists (EOC and EOR) to shape endo-training blocks with J-shaped simulated canals. Each operator prepared 5 canals per system, giving 20 canals per group. Pre- and post-operative images of simulated canals were superimposed. The total amount of straightening and the change in the radius of curvature and centering ratios were determined. The results were analyzed using two-way analysis of variance, with operator experience and file system as fixed factors, followed by Tukey's post hoc comparison at a significance level of 95%. RESULTS: The One RECI system produced significantly greater overall straightening than the One Curve system (p = 0.016), while operator experience had no significant effect on straightening or on the change in the radius of curvature (p > 0.05). Operators experience significantly affected the centering ratio from the apical third to the center of the curvature (p < 0.05), with inexperienced operators generally achieving higher centering ratios, except near the center of curvature. No effect of experience was found at the apical terminus or in the coronal, straight portion of the canal (p > 0.05). Inexperienced operators using the One RECI system achieved significantly higher centering ratios than all other groups in the apical third (p < 0.05). No significant experience × system interaction was found for any parameter. CONCLUSION: Within the limitations of the present study, shaping outcomes with single-file NiTi systems were influenced by both operator experience and instrument kinematics, although no significant interaction between these factors was detected.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Choosing the Right File for the Canal: Clinical Applications of Two Different Single-File Reciprocating Systems.Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995) · 2026
- Comparative evaluation of shaping ability of EdgeOne-R Utopia, One Reci, and WaveOne Gold in severely curved simulated root canals: an in vitro study.BMC oral health · 2026
- Micro-CT Evaluation of Shaping Ability, Canal Transportation, and Centering Ability of Continuous Rotary and Reciprocating Systems in Maxillary Premolars.Medical science monitor : international medical journal of experimental and clinical research · 2026
- A Comparative Evaluation of the Cyclic Fatigue Resistance of Three Nickel-Titanium Rotary File Systems in a Simulated Curved Canal: An In Vitro Study.Cureus · 2026
- Cyclic Fatigue Resistance and Fractured Fragment Length of Three NiTi Rotary Systems: An In Vitro ComparisonOral · 2026
- Association Between Cross-Sectional Geometry and Cyclic Fatigue Resistance of Nickel-Titanium Endodontic Instruments: A Systematic Review.Journal of functional biomaterials · 2026