Effect of different modeling agents on the shear bond strength between incremental layers of resin composite: an in vitro study.
Nevin Kaptan Akar, Helin Öztop, Enes Ordukaya, Göktuğ Yersel, Neslihan Tekçe
Department of Orthodontics, Faculty of Dentistry, Kocaeli University, Kocaeli, Turkey. · Department of Restorative Dentistry, Faculty of Dentistry, Kocaeli University, Yuvacık, Başiskele, Kocaeli, Turkey.
Key points
From the paper's conclusion- Within the limitations of this in vitro study, neither the type of modeling liquid nor the application time or polymerization protocol significantly affected the shear bond strength between resin composite increments under the tested conditions.
Abstract
BACKGROUND: Modeling liquids are widely used in restorative dentistry to facilitate the adaptation and contouring of resin composites during incremental layering. Because no standardized, manufacturer-recommended protocol exists for their type, application time, or polymerization sequence, their influence on the bond strength between composite increments remains unclear. This in vitro study evaluated the effect of three modeling liquids, two application times, and two polymerization protocols on the interlayer shear bond strength of a resin composite. MATERIALS AND METHODS: Shear bond strength specimens were prepared using a single anterior resin composite (Estelite Sigma Quick 2, A2; Tokuyama Dental, Japan). A 2-mm composite substrate was built in two 1-mm increments, and a 1-mm-high, 2.60-mm-diameter composite cylinder was bonded to it through a silicone guide. Three modeling liquids (GC Modeling Liquid, Signum Liquid, and Composite Wetting Resin) were applied to the substrate surface for 5-10 s under two polymerization protocols: protocol C1, in which the modeling-liquid-coated surface was light-cured before the cylinder was placed, and protocol C2, in which the modeling-liquid-coated surface and the cylinder were co-cured in a single step. A control group received no modeling liquid. This yielded a 3 × 2 × 2 factorial design (12 experimental groups) plus the control group (n = 12 per group). Specimens were stored in distilled water at 37 °C for 24 h and tested in shear at 1 mm/min according to ISO 29,022. Main effects and interactions were analyzed by three-way ANOVA; the control group was compared with the experimental groups by one-way ANOVA (α = 0.05). RESULTS: Modeling liquid type, application time, and polymerization protocol had no statistically significant effect on shear bond strength, and no significant two- or three-way interactions were detected (all p > 0.05). Mean (± SD) values were 21.84 ± 8.79 MPa for GC Modeling Liquid, 21.70 ± 8.56 MPa for Signum Liquid, and 22.81 ± 10.43 MPa for Composite Wetting Resin; the control group was 17.73 ± 3.51 MPa (liquid type p = 0.815, application time p = 0.071, polymerization protocol p = 0.960; all interactions p > 0.05). Failures in the experimental groups were mainly mixed and cohesive, whereas the control failed predominantly at the interface (adhesive). CONCLUSION: Within the limitations of this in vitro study, neither the type of modeling liquid nor the application time or polymerization protocol significantly affected the shear bond strength between resin composite increments under the tested conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of immediate and delayed composite restoration on shear bond strength to remineralized initial enamel lesions: an in vitro study.The Saudi dental journal · 2026
- Shear Bond Strength of TheraCal PT and Calcium Silicate-Based Cement to a Flowable Composite Resin According to Bonding Strategy.Journal of functional biomaterials · 2026
- Interfacial Bond Strength of CAD/CAM Resin Composites on Dentin vs. Composite Substrates: Influence of Dual-Cure and Self-Adhesive Resin CementsPolymers · 2026
- Effects of chemical surface treatment on shear bond strength between additively manufactured denture base and autopolymerizing resins in non-aged conditions.Journal of prosthodontic research · 2026
- Efficacy of light-cured luting systems for CAD-CAM milled resin indirect restorations.Revista cientifica odontologica (Universidad Cientifica del Sur) · 2026
- Marginal gap formation and fracture strength of indirect inlay restorations cemented with preheated resin composites: an in vitro study.BMC oral health · 2026