Comparison of diagnostic success between the BF-P290 and BF-P260F bronchoscopes in patients with peripheral pulmonary lesions: a retrospective study
Naoaki Tsuji, Hayato Kawachi, Chie Yamamoto, Masaki Ishida, Naoya Nishioka, Masahiro Iwasaku, Tadaaki Yamada, Koichi Takayama
Key points
From the paper's conclusion- We compared the diagnostic success of BF-P290 and BF-P260F for peripheral lung lesions and identified associated predictors.
Abstract
Background Bronchoscopy is widely used to diagnose peripheral pulmonary lesions; however, success remains limited by complex distal airway anatomy. The BF-P290 is a next-generation thin bronchoscope with high-resolution imaging, improved axial rotation, and greater shaft flexibility than its predecessor, the BF-P260F. We compared the diagnostic success of BF-P290 and BF-P260F for peripheral lung lesions and identified associated predictors. Methods This single-center retrospective study included consecutive patients who underwent diagnostic bronchoscopy with BF-P290 or BF-P260F for suspected peripheral pulmonary lesions between April 2022 and March 2025. Diagnostic success was defined as a specific malignant or specific benign pathological diagnosis obtained from bronchoscopic specimens. Multivariable logistic regression was used to adjust for lesion and imaging characteristics, and sensitivity analyses were performed to account for operator, fiscal year, and preprocedural clinical suspicion. Results Among 287 patients (BF-P290, n = 90; BF-P260F, n = 197), the overall diagnostic success was 62.0%. The BF-P290 group had a significantly higher diagnostic success rate than the BF-P260F group (72.2% vs. 57.4%; odds ratio [OR] 1.93, 95% confidence interval [CI] 1.09–3.47; p = 0.018). In the multivariable analysis, BF-P290 use remained independently associated with diagnostic success (adjusted OR 1.93, 95% CI 1.07–3.54; p = 0.031), with computed tomography (CT) bronchus sign positivity as the strongest predictor (adjusted OR 8.57, 95% CI 2.96–31.49; p < 0.001). The sensitivity analyses accounting for operator, fiscal year, or preprocedural clinical suspicion (1.93–2.04) revealed similar adjusted ORs, whereas the association was attenuated among patients with suspected lung cancer (adjusted OR 1.63, 95% CI 0.85–3.20). In a post hoc exploratory analysis, the association was observed for left but not right lung lesions (interaction p = 0.004). Conclusions The BF-P290 was independently associated with higher diagnostic success than the BF-P260F for peripheral pulmonary lesions. The difference observed for left lung lesions was a post hoc, hypothesis-generating finding, and these associations warrant further prospective evaluation. CT bronchus sign positivity was a strong predictor of diagnostic success. Combining bronchoscope selection with preprocedural lesion stratification may optimize the diagnostic strategy. Clinical trial number Not applicable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- VITAL Study: Real-World Comparison of Robotic and Imaging-Guided Bronchoscopy : Impact of Real-Time Imaging and Tool-Lesion Alignment on Diagnostic Yield.Respiratory medicine · 2026
- Diagnostic Performance and Safety Profile of Shape-sensing Robotic-assisted Bronchoscopy in Peripheral Pulmonary Lesions: A Systematic Review and Meta-Analysis.Respiration; international review of thoracic diseases · 2026
- Comparative diagnostic performance of robotic, electromagnetic navigation, and fluoroscopy bronchoscopy for lung cancer in peripheral pulmonary lesions: a prospective, multicenter, parallel-controlled trial.Journal of advanced research · 2026
- Advanced Bronchoscopic Approaches to Peripheral Pulmonary Lesions: a Narrative Review of Current and Emerging Techniques.Pulmonary therapy · 2026
- Robotic-Assisted Bronchoscopy for Peripheral Pulmonary Lesions: Current Evidence, Clinical Applications, and Future Directions.Diagnostics (Basel, Switzerland) · 2026
- First Korean experience with shape-sensing robotic-assisted bronchoscopy integrated with mobile cone-beam CT: Results from the prospective ULSAN-ION study.Lung cancer (Amsterdam, Netherlands) · 2026